Technical data
What if ... Possible fault Solution
The items have stains. The rinse aid dosage is set
too low.
Increase the dispense
amount for rinse aid.
The container for rinse aid
is empty.
Refill rinse aid.
Poor cleaning results Baskets and Inserts were
loaded faulty or too full.
Rearrange items.
Do not overload the
baskets and inserts.
The soiling dried on the
items.
Do not allow dirty
instruments to sit for over 6
hours before running the
Disinfection Vario cycle.
A spray arm is blocked. Arrange the items so they
do not block the spray
arms.
Spray arm jets or jets at
the inserts are clogged.
Check and clean the spray
jets.
The basket or insert is not
properly connected to the
water connection.
Adjust the water intake
connection of the basket or
insert properly.