Technical data
Dispensing neutralizer with the DOS module
Setting the dosage
The dispensing concentration for neutralizer must be set according to the
manufacturer's specifications or the requirements.
Step Display / Result
^
Press "Drying" 0 until E02 appears
in the display.
E02
^
Turn the program selector to the
1-o'clock-position.
The dispensing concentration
which has been set will appear in
the display, e.g. 0.10 = 0.10%
^ Press and hold "Display" ß until the
desired value appears in the display,
e.g. 0.20.
0,20
The dispensing concentration level
has now been set.
Dispensing concentration set:
Setting Dosage Setting Dosage
.10 20 ml .60 70 ml
.20 30 ml .70 80 ml
.30 40 ml .80 90 ml
.40 50 ml* .90 100 ml
.50 60 ml 1.0 110 ml
Programming functions
39