Fitting Instructions
en - Connection
10
When setting the dosage please note:
For cleaning agent dosage the dispensing concentration must be
doubled in the machine controls (see the specifications for setting
dispensing concentration in the Operating instructions).
Strain relief for
dispensing hoses
The strain relief provided with the DOS module for the dispensing
hoses is fitted to the bottom right hand side of the back of the ma-
chine to prevent the hoses from dislodging themselves from the dis-
penser connections during use.
Connecting the
dispensing hoses
The DOS module is tested at the factory for functionality.
Any residues of the harmless test medium are a result of this testing
and not evidence of previous use.
Pull the safety cap off the end of the hose and remove the protect-
ive foil from the siphon.
Connect the hose with the dispenser connection on the washer-dis-
infector.
Connections for the dispensing hoses are located at the back of the
washer-disinfector
(These are described in detail in the Operating instructions for your
washer-disinfector).