operating instructions
–
If several gas surfaces are installed
under the hood, the total output must
be considered when determining the
minimum safety distance.
–
Be sure to follow the minimum safety
distances given by the gas cooktop
manufacturer to easily flammable
materials e.g. upper cabinets.
–
If local building codes require a
greater safety distance, follow their
requirement.
–
If there is more than one appliance
beneath the hood and they have
different minimum safety distances
always select the greater distance.
See "Important Safety Instructions"
for further information.
The installation procedure differs
depending on the model and venting
method.
Before beginning the installation:
^
Read all instructions.
^
Determine height (S), regarding the
user’s body height, i.e. a comfortable
height for the user.
However, the greater the distance the
less effectively cooking odors are
drawn in.
If the hood is fitted flush to the ceiling,
regard the possible unit height when
selecting the installation height.
Standard unit height (H):
Air Extraction ........29
5
/
16
"-41
9
/
16
"
..................(745 - 1055 mm)
Recirculation........34
7
/
16
"-46
11
/
16
"
..................(875 - 1185 mm)
To fit the lower chimney section, the
distance between the top of the
chimney and the ceiling must be at
least
7
/
8
" (20 mm).
Appliance dimensions
28