Technical data

Total connected load* .........260W
- Fan motor*.................200W
- Hob lighting ..............3x20W
Voltage ................. AC230V
Frequency .................. 50Hz
Fuse rating ....................5A
Electrical cable length .........1.5m
Weight
DA 5690 W ..................28kg
DA5690WEXT ..............25kg
Fan performance*
Extraction power according to
EN 61591
Extraction system C 150 mm:
Level 1...................200m
3
/h
Level 2...................300m
3
/h
Level 3...................400m
3
/h
IS (Intensive setting) ........640m
3
/h
Extraction system C 125 mm:
Level 1...................180m
3
/h
Level 2...................280m
3
/h
Level 3...................380m
3
/h
IS (Intensive setting) ........580m
3
/h
Recirculation with charcoal filter:
Level I ...................150m
3
/h
Level 2...................210m
3
/h
Level 3...................330m
3
/h
IS (Intensive setting) ........490m
3
/h
Special accessory for recirculation
mode:
Conversion kit DUW 20
Miele charcoal filter DKF 12-1
* For EXT models, the connected load
and extraction power will depend on
the type of external motor fitted.
...EXT models:
Length of connection cable to external
motor.......................1.9m
Technical data
34