Installation Instructions DA424V-6 en - CA Installation, repair and maintenance work should be performed by a Miele authorized service technician in accordance with national and local safety regulations and the provided installation instructions.
Installation Before installation Before installing the appliance, read all of the information contained in this chapter and also in the "IMPORTANT SAFETY INSTRUCTIONS" section. 4 telescopic extension piece holders for aligning and securing the telescopic chimney Installation parts 4 screws M³/₁₆" x ⁵/₁₆" (M4 x 8.5 mm) for securing the telescopic extension piece holders. 4 screws, 6 ⁹/₁₆" x 4 ⁵/₁₆" (7 x 110 mm) and 4 plugs, ³/₈" x 3 ¹/₈" (10 x 80 mm) for securing the hood to the ceiling.
Installation Appliance dimensions a Mounting area for the exhaust ducting and power cable. In recirculation mode, only the power cord is required. b Alternative installation with spacer frame c A power cord is required to connect the hood to the outlet in the ceiling. With extraction mode flexible ducting is also required.
Installation Distance between cooktop and ventilation hood (S) Provided a larger distance is not given by the manufacturer of the cooktop, follow the minimum safety distances between a cooktop and the bottom of the hood. Please also observe the information contained in the "IMPORTANT SAFETY INSTRUCTIONS" section. Minimum distance S Cooking appliance Miele range Non-Miele range Electric Cooktops 24" (610 mm) Electric Barbeques and Fryers 26" (660 mm) Multiburner Gas Cooktops ≤ 43,000 BTU/hr (12.
Installation Installation recommendations Structural support – When selecting an installation height, always take the user height into consideration. Users should have ample space to work comfortably on the cooktop and reach the ventilation hood controls with ease. – Please note that the greater the distance from the cooktop, the less effective the hood is at drawing in the cooking vapors. – To achieve optimal vapor extraction, make sure that the hood covers the cooktop.
Installation 85 5/8" m 22 /8" 0 8 m 22 0 mm For vented mode: dai3435aus Draw two intersecting lines on the ceiling. – Place a section of the exhaust ducting in the ceiling and feed it down through the cross-sectional area as illustrated. Exhaust ducting of approx. 8" (200 mm) length is required between the ceiling and the hood exhaust socket. – Secure the exhaust ducting to the exhaust socket, e.g. with a hose clip (available as an optional accessory) on flexible ducting.
Installation Use a knife to release the four spacers and the two covers from the spacer frame supplied. Drill four holes ³/₈" (10 mm), approx. 4 ¹/₂" (115 mm) deep for the plugs supplied. Use the spacer frame as a drilling template. Place it on the ceiling with the arrows pointing forwards. Using the notches, align the spacer frame on the intersecting lines and make pencil marks for the drill holes.
Installation Loosen the two telescopic extension piece holders from the installation frame. The spacer frame can be installed between the chimney and the ceiling. This creates a shadow which gives the illusion of a gap between the ceiling and the chimney. This is useful if the ceiling is not level or is uneven. The hood is aligned vertically with the spacers supplied. Visual irregularities between the chimney and the ceiling are then concealed by the shadow.
Installation Mount the spacer frame onto the installation frame. Hang the hood on the four screws, making sure the controls are at the front. If using the spacer frame, place the two covers into the fixing holes.
Installation Place the exhaust ducting onto the exhaust socket. Connect the power cord. See "Electrical connection." Align the installation frame and secure it with the screws. The spacers, which were removed from the spacer frame at the start, can be used to align the hood vertically.
Installation Remove the grease filters from the hood. Push the tower and the telescopic extension piece upwards and bend the retaining tabs outwards again to prevent the tower and telescopic extension piece from slipping down again. Remove the safety screw for the tower on the inside of the frame.
Installation When the canopy is lowered, the safety distance to the cooker may not be exceeded (see "Appliance dimensions"). The height range for the appliance can be extended or limited by moving the limit switch. Press the button. The canopy will be lowered to its fullest extent. Check the distance to the cooker. If the safety distance is undershot, the limit switch must be readjusted. Fit the four telescopic extension piece holders between the tower and the telescopic extension piece.
Installation Move the canopy to the required height by pressing the button and stop it by pressing the or button. Screw on the limit switch opposite the guide. Hold the chimney securely, bend back the retaining tabs and carefully lower it. The chimney will locate in the cut-out in the canopy.
Installation 1x T20 M4x16 Insert the safety screw on the inside. Carefully remove the protective foil from the grease filters. Reinsert the grease filters.
Exhaust duct WARNING: Danger of toxic fumes. Gas cooking appliances release carbon monoxide that can be harmful or fatal if inhaled. To reduce the risk of fire and to properly exhaust air, the exhaust gases extracted by the hood should be vented outside of the building only. Do not vent exhaust air into spaces within walls or ceilings or in attics, crawl spaces or garages. To reduce the risk of fire, only use metal ductwork.
Exhaust duct Condensate trap In addition to insulating the exhaust duct, we recommend installing a condensate trap to collect and evaporate any condensate which might accumulate. Condensate traps are available for exhaust ducts with a diameter of 5" (125 mm) or 6" (150 mm). When installing a condensate trap, make sure that it is positioned vertically and, if possible, directly above the hood outlet duct collar. The arrow on the housing indicates the direction of airflow.
Electrical connection WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: All electrical work should be performed by a qualified electrician in strict accordance with national regulations (for USA: ANSI-NFPA 70) and local safety regulations. Installation, repairs and other work by unqualified persons could be dangerous. Ensure that power to the appliance is OFF while installation or repair work is performed.
Activating Con@ctivity 2.0 Installation of the Con@ctivity 2.0 stick In order for you to be able to use the Con@ctivity 2.0 function, the cooktop must be equipped with a Con@ctivity 2.0 stick. See the relevant installation instructions of the Con@ctivity 2.0 stick. Activating the ventilation hood The cooktop and hood must be switched off. Press the delayed shut-down button 515 for approx. 10 seconds until the 1 indicator appears in the fan level display.
Activating Con@ctivity 2.0 Activating the cooktop Activation failed While the ventilation hood is searching for a wireless connection, start activation on the cooktop. More information can be found in the operating instructions for the cooktop. If a wireless connection cannot be established despite activation of the Con@ctivity function on the ventilation hood and cooktop, the function must first be deactivated and then reactivated on both appliances.
Service and warranty For faults that you cannot resolve on your own, please contact your Miele dealer or Miele Technical Service. The telephone number for the Technical Service Department is listed at the back of these instructions. When contacting Miele, please state the model and serial number of your ventilation hood. These can be found on the data plate. Location of the data plate The data plate is visible once you have removed the grease filters.
Technical data Fan motor 350 W Height adjustment motor 150 W LED cooktop lighting 4x3W Total connected load 512 W Voltage, frequency Fuse rating Weight 120 V AC, 60 Hz 15 A 107.8 lbs (49 kg) Contains FCC ID: 2ACUWEI8800 IC: 5669C-EI8800 This device complies with Part 15 of the FCC Rules and with Industry Canada licence-exempt RSS standard(s).
Please have the model and serial number of your appliance available before contacting Technical Service. U.S.A. Canada Miele, Inc. Importer Miele Limited National Headquarters 9 Independence Way Princeton, NJ 08540 Phone: 800-843-7231 609-419-9898 609-419-4298 Fax: www.mieleusa.com Technical Service & Support Nationwide Phone: 800-999-1360 888-586-8056 Fax: TechnicalService@mieleusa.com Headquarters and Miele Centre 161 Four Valley Drive Vaughan, ON L4K 4V8 www.miele.
DA 424V-6 en-US M.-Nr.