Technical data

Table Of Contents
Installation
27
a
Extraction
b
Recirculation
c
Ventilation grille positioned at the top for recirculation
de
(Only d
is required for recirculation mode cooker hoods). The shaded area
represents the wall or ceiling area for the ducting cut-out and for the
connection socket. Recirculation cooker hoods only need a connection
socket to be fitted.
Connection for air extraction 150 mm, or 12
5 mm with reducing collar.
Safety distance between hob and cooker hood (S)
When planning the installation height of your cooker hood, the minimum safety
distance
between the top of a cooker or hob and the bottom of the cooker
hood is as follows, unless a greater distance is specified by the manufacturer of
your cooking appliance.
See "Warning and Safety" instructions for further information.
Cooking appliance Minimum distance S
Electric hob 450 mm
Electric grill, deep fat fryer (electric) 650 mm
Multi-burner gas hob,
t
otal output 12.6 kW, no burner > 4.5 kW
650 mm
Multi-burner gas hob,
t
otal output > 12.6 kW and 21.6 kW,
no burner > 4.8 kW.
760 mm
Multi-burner gas hob,
t
otal output > 21.6 kW,
or multi-burner gas hob where one burner > 4.8 kW.
Not possible
Single burner gas hob, output
6 kW.
650 mm
Single burner gas hob, output >
6 kW and 8.1 kW.
760 mm
Single burner gas hob, output >
8.1 kW
Not possible