Operating and Installation Instructions Ventilation System DA 289-4 To prevent accidents and machine damage, read these instructions before installation or use. UV M.-Nr.
Contents IMPORTANT SAFETY INSTRUCTIONS Functional description Guide to the hood Operation Turning on the fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Selecting the power level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Delayed Shut Down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Turning off the fan . . . . . . . . . . . . . . . . . . . . . . . . .
IMPORTANT SAFETY INSTRUCTIONS Read these Operating Instructions carefully before installing or using the Ventilation System. This appliance is intended for residential use only. Use the appliance only for its intended purpose. The manufacturer cannot be held responsible for damages caused by improper use of the hood. This appliance complies with current safety requirements. Improper use of the appliance can lead to personal injury and material damage.
IMPORTANT SAFETY INSTRUCTIONS This equipment is not designed for maritime use or for use in mobile installations such as recreational vehicles or aircraft. However, under certain conditions it may be possible for an installation in these applications. Please contact the nearest Miele dealer or the Miele Technical Service Department with specific requirements.
IMPORTANT SAFETY INSTRUCTIONS , WARNING - TO REDUCE THE RISK OF A COOKTOP GREASE FIRE: Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers may ignite. Heat oils slowly on low or medium settings. Always turn the hood on when cooking at high heat or when cooking flaming foods. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter. Use proper pan size. Always use cookware appropriate for the size of the surface element.
IMPORTANT SAFETY INSTRUCTIONS Installation , WARNING To reduce the risk of fire only use metal ductwork. When installing the hood, make sure that a minimum safety distance of 14 3/8" is maintained between a Miele cooktop and the bottom of the hood. If local building codes require a greater safety distance, follow their requirement. For non-Miele cooking appliances maintain the safety distances recommended by the cooktop manufacturer.
Functional description The ventilation hood works by air extraction. The air is drawn in and cleaned by the grease filters and directed outside. The hood comes equipped with a non-return flap. This flap automatically closes when the hood is turned off so that no exchange of outside air and room air can occur. When the hood is turned on, the air pressure of the exhaust fan automatically opens the flap blowing the inside air and cooking odors outside.
Guide to the hood 8
Guide to the hood a Chimney extension h Light button b Chimney This button dims the light or turns it on and off. c Canopy The lighting can be used independently of the fan. d Control panel e Overhead lighting i On/Off button j Fan power selection f Grease filter Four fan speed selection g Air intake panel k Delayed Shut Down This button activates the Delayed Shut Down feature. The fan can be set to turn off automatically after either 5 or 15 minutes.
Operation Turning on the fan Automatically switching back the intensive power level The intensive level "4" can be programmed to automatically switch back to level "3" after 10 minutes. ^ Press the On/Off button. Selecting the power level ^ Use the "–/+" controls to select the desired power level. + = increases the fan speed – = decreases the fan speed ^ Turn the fan and the lights off. ^ Press and hold the "Delay Shut down" button for 10 secs. The first indicator lights.
Operation Fan performance If the power level indicators "1" and "4" flash the automatic switch back is not activated. ^ To activate the automatic switch back press the "+" button. The maximum air flow capacity is 625 cfm. Factors such as narrow duct diameter and bends will affect this value. Level 1 operates at 40% capacity Level 2 operates at 60% capacity Level 3 operates at 80% capacity Level 4 operates at 100% capacity The power level indicators "1" and "4" light continuously.
Operation Delayed Shut Down If odors or smoke remain in the kitchen after cooking has been completed, the Delayed Shut Down feature can be selected to allow the hood to continue running for either 5 or 15 minutes. Turning off the fan ^ Press the On/Off button to turn the fan off. The indicator goes out. ^ Press the Delayed Shut Down button while the fan is still running.
Operation Turning the lighting on/off Dimming the lighting The overhead lighting can be turned on and off independently of the fan. The brightness of the lighting can be adjusted. ^ While the lighting is turned on, press the light button. The lighting will dim until the button is released. ^ Press the light button briefly to turn on the lighting. The light button indicator illuminates. ^ Press the light button briefly again to turn off the lighting. The light button indicator will go out.
Operation Grease filter timer Checking the grease filter timer A timer monitors the hours of fan operation. The indicator for the grease filter will light after 30 hours of operation. The grease filter and air intake panel must then be cleaned. To check the percentage of time already used: After the grease filter has been cleaned and put in place, the grease filter timer must be reset. ^ To do this, press the grease filter button for about 3 seconds. ^ Press the On/Off button to turn the fan on.
Operation Reprogramming the grease filter timer The grease filter timer is preset to 30 hours. This time can be lengthened or shortened to 20, 30, 40 or 50 hours. – A time of 20 hours should be programmed in kitchens with frequent pan or deep frying. The indicator for the grease filter and one of the "–/+" indicators will flash.
Cleaning and care Stainless steel Before cleaning or servicing the hood, disconnect it from the power supply by either removing the fuse, unplugging it from the outlet or manually "tripping" the circuit breaker. Cleaning the casing ,Never use abrasive cleaners, scouring pads, steel wool or caustic (oven) cleaners on the hood. They will damage the surface. ^ The air intake panel, exterior surfaces and controls can be cleaned with warm water and liquid dish soap applied with a soft sponge.
Cleaning and care Grease filter and air intake panel Removing the air intake panel The reusable metal grease filter removes solid particles from the vented kitchen air (grease, dust, etc). The grease filter and the air intake panel should be cleaned every 3 - 4 weeks or whenever the grease filter indicator lights. Keep the grease filter clean to prevent a fire hazard. ^ To remove the air intake panel gently pull out and downward, shifting the lower part a bit to the right. Lift it out of the latches.
Cleaning and care Cleaning the grease filters ^ By hand: use a scrub brush with a solution of warm water and mild detergent. Do not use the pure detergent, aggessive all purpose cleaners, oven sprays or limescale removers. They could destroy the filters. ^ In a dishwasher: place the filters vertically in the lower basket, making sure that the spray arm is not blocked. Use a hot temperature program, e.g. "Heavy Soil" or "Pots and pans". Use the recommended amount of dishwasher detergent.
Cleaning and care Changing the light bulbs Before changing the light bulbs, disconnect the hood from the power supply by either removing the fuse, unplugging it, or manually "tripping" the circuit breaker. When in use halogen bulbs become extremely hot, and they can burn your hands. Do not attempt to change the bulbs until they have had sufficient time to cool. Do not touch the bulb surface. Fingerprints or body oils deposited on the bulb will decrease its life.
After Sales Service Repairs MieleCare In the event of a fault which you cannot easily fix yourself, please contact the Miele Technical Service Department at the address on the back of this booklet. MieleCare, our Extended Service Contract program, gives you the assurance of knowing that your appliance investment is covered by 5 years of worry free ownership.
Installation Instructions
Caring for the environment Disposal of packing material Disposal of an old appliance The cardboard box and packing materials protect the appliance during shipping. They have been designed to be biodegradable and recyclable. Please recycle. Old appliances may contain materials that can be recycled. Please contact your local recycling authority about the possibility of recycling these materials. To prevent suffocation of children, ensure that any plastic wrappings, bags, etc.
Installation accessories 24
Installation accessories a 3 protective shields prevent scratches to the chimney during installation. b Upper retaining plate secures the chimney extension. c Middle retaining plate for additional stability of the chimney. d 2 hose clips for securing the ducting. e 1 reducing collar for use with 5" (125 mm) exhaust ducting. Caution: During the installation process, please be careful of sharp edges that can cause harm. 5 large headed screws 5 x 40 mm for securing the retaining plates and the canopy.
Plywood backing The majority of the weight of the installed ventilation system will be supported by the lower retaining plate. It must be firmly attached to the stud framing behind the drywall. If studs are not available in the required locations, a plywood backing (min. 1/2" (13 mm) thick) spanning at least two studs must be installed. Failure to adequately support the weight as stated may result in the ventilation system falling off the wall, causing personal injury and property damage.
Electrical data All electrical work should be performed by a qualified electrician in strict accordance with national and local safety regulations. Installation, repairs and other work by unqualified persons could be dangerous. The manufacturer cannot be held responsible for unauthorized work. Ensure that power to the appliance is OFF while installation or repair work is performed. Important The hood comes equippped with a 5 ft (1.
Appliance dimensions 28
Appliance dimensions 1) and 2) Cut out area in wall or ceiling for entrance of 6" (150 mm) ductwork or 5" (125 mm) ductwork with a reducing collar. Do not install this exhaust hood over cooktops burning solid fuel. Distance between cooktop and hood (S) The installation procedure differs depending on the model and venting method. Before beginning the installation: ^ Read all instructions.
Installation Installation instructions Dismantling ^ See the enclosed installation instruction sheet. If the hood needs to be disassembled, follow the instructions on the installation sheet in the reverse order. ^ Please read the "Important Safety Instructions" and Installation instructions before installing this hood. A lever is enclosed for easier removal of the chimney extension. Protective film The casing is covered with a protective film to prevent scratching during transport.
Air extraction ,WARNING Danger of toxic fumes. Gas cooking appliances release carbon monoxide that can be harmful or fatal if inhaled. The exhaust gases extracted by the hood should be vented outside of the building only. Do not terminate the exhaust ducts in attics, garages, crawlspaces, etc. To reduce the risk of fire, only use metal ductwork. Please read and follow the "IMPORTANT SAFETY INSTRUCTIONS" to reduce the risk of personal injury. Follow all local building codes when installing the hood.
Air extraction Condensate trap optional accessory If the exhaust is ducted into an inactive flue, the air must be expelled parallel to the flow direction of the flue. Never connect an exhaust hood to an active chimney, dryer vent, vent flue, or room venting ductwork. Seek professional advice before connecting an exhaust hood vent to an existing, inactive chimney or vent flue. Important! If the ductwork runs through rooms, ceilings, garages, etc.
Alteration rights reserved / 1006 M.-Nr.