Technical data

a Air extraction
b Air recirculation
c Ventilation grille positioned at the top
for recirculation
d and e:
(e is not required for recirculation
mode rangehoods):
The shaded area represents the wall or
ceiling area for the vent cut-out and for
fitting the connection socket.
For recirculation mode, only a
connection socket needs to be fitted.
Connection for air extraction
C 150 mm, or C 125 mm with reducing
collar.
Safety distances between cooktop
and rangehood (S)
The minimum safety distances
between the top of a cooktop and
the bottom of the rangehood are
as follows, unless a greater
distance is specified by the
manufacturer of your cooking
appliance:
Cooking appliance Distance
S
Electric cooktop 600 mm
Open electric grill 650 mm
Deep fat fryer (electric) 650 mm
Multi-burner gas cooktop
with maximum 45.4 MJ/h
total output, with no burner
having a greater output
than 16.2 MJ/h.
650 mm
Multi-burner gas cooktop
with total output greater
than 45.4 MJ/h, or a gas
cooktop including a single
burner with an output
greater than 16.2 MJ/h.
760 mm
Single gas cooktop with a
maximum output of
21.6 MJ/h
650 mm
Single gas cooktop with a
maximum output greater
than 21.6 MJ/h
760 mm
See "Warning and Safety"
instructions for further information.
Appliance dimensions
31