Technical data
Power Management System
The Power Management System
contributes to saving energy.
It ensures that the fan automatically
switches to a lower power level and that
the lighting switches off.
–
If the Intensive setting is selected,
the rangehood switches to power
level 3 after 5 minutes, level 2 after
two hours, and level 1 after a further
30 minutes. After another 30 minutes,
the fan will switch off altogether.
–
If fan power levels 2 or 3 are
selected, the rangehood switches to
the level below after two hours and
then lower again in 30-minute steps
until finally switching off.
– If level 1 is selected, the fan switches
off after two hours.
– Cooktop lighting will automatically
switch off after 12 hours.
If you wish, you can deactivate the
Power Management System.
^
Touch the run-on sensor ¢ for
approx. 10 seconds until the 1 power
level sensor lights up.
^
Touch in turn
–
the cooktop lighting touch control I,
–
the 1 sensor, and
–
the cooktop lighting touch control I
again.
If the Power Management System is
activated, 1 and IS will light up
constantly.
^ Press the 1 sensor to deactivate the
Power Management System.
The indicator lights for fan power
levels 1 and IS will flash.
Touch the IS sensor to activate the
Power Management System again.
^ Confirm by pressing the run-on
sensor ¢.
If you do not confirm your selection
within 4 minutes, the rangehood will
automatically revert to the original
setting.
Operation (manual operation)
22