Operating and installation instructions Cooker hood DA 416-4, DA 419-4 To avoid the risk of accidents or damage to this appliance it is essential to read these instructions before it is installed and used for the first time. en - GB M.-Nr.
Contents Caring for the environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Warning and Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Guide to the appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Modes of operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Operation . . . . . . . . . . . . . . . . . . . . .
Caring for the environment Disposal of the packing material The transport and protective packing has been selected from materials which are environmentally friendly for disposal, and should be recycled. Packaging e.g. cling film, polystyrene and plastic wrappings must be kept out of the reach of babies and young children.
Warning and Safety instructions This appliance complies with all relevant local and national safety requirements. Inappropriate use can, however, lead to personal injury and damage to property. To avoid the risk of accidents and damage to the appliance, please read these instructions carefully before using it for the first time. They contain important information on the safety, installation, use and maintenance of the appliance.
Warning and Safety instructions Technical safety ~ Before installation, check the cooker hood for visible signs of damage. Under no circumstances should you use a damaged appliance. It could be dangerous. ~ Before connecting the appliance to the mains supply, make sure that the voltage and frequency details given on the data plate correspond with the on-site electricity supply, otherwise the appliance could be damaged. Consult a qualified electrician if in any doubt.
Warning and Safety instructions ~ Do not connect the appliance to the mains electricity supply by a multi-socket unit or an extension lead. These do not guarantee the required safety of the appliance (e.g. danger of overheating). Using at the same time as other heating appliances that depend on the air from the room Warning - danger of toxic fumes ~ This appliance may only be used in mobile installations if a risk assessment of the installation has been carried out by a suitably qualified engineer.
Warning and Safety instructions In order to ensure safe operation, and to prevent gases given off by the heating appliances from being drawn back into the room when the cooker hood and the heater are in operation simultaneously, an underpressure of 0.04 mbar (4 pa) is the maximum permissible in the room. One of the following technical measures may be necessary to ensure safe operation.
Warning and Safety instructions Correct use ~ Never use an open flame beneath the cooker hood. To avoid the danger of fire, do not flambé or grill over an open flame under the cooker hood. When switched on, the cooker hood could draw flames into the filter. Fat particles drawn into the cooker hood present a fire hazard. ~ When using the cooker hood over a gas hob, ensure that any burners in use are always covered by a pan. Switch the cooking zone off when a pan is removed, even for a short time.
Warning and Safety instructions ~ Safety regulations prohibit the fitting of a cooker hood over solid fuel stoves. ~ All ducting, pipework and fittings must be of non-flammable material. These can be obtained from the Miele Spare Parts department or from builders' merchants. ~ The appliance must not be connected to a chimney or vent flue which is in use. Neither should it be connected to ducting which ventilates rooms with fireplaces.
Guide to the appliance 10
Guide to the appliance a Telescopic extension piece b Tower c Canopy d Touch controls e Grease filters f Recirculation grille (only for recirculation mode) g Hob lighting h Charcoal filter (special accessory for recirculation mode) i On/Off control for the fan j Controls to select fan power level k On/Off control for hob lighting 11
Modes of operation The cooker hood works with . . . air extraction: . . . air recirculation: (available as an optional extra with a conversion kit and charcoal filter: see "Technical Data") The air is drawn in and cleaned by the grease filters and directed outside. If the on-site ventilation system does not have a non-return flap, the non-return flap supplied with the appliance must be fitted in the exhaust socket in the motor unit.
Operation To switch the fan on s ^ Press the On/Off control s. The fan will come on at power level lI. If the cooker hood has been connected to a window contact switch via the Miele DSM 400 control module, then the fan cannot be switched on if the window is shut. The s symbol flashes. Automatic switch-off of the Intensive setting You can set the Intensive setting so that it only runs for 10 minutes before reverting automatically to level III.
Operation To switch the fan off s ^ Press the On/Off control s to switch the fan off. The s symbol goes out. It is advisable to run the fan for a few minutes after cooking has finished to neutralise any lingering odours in the air, whether you are using air extraction or recirculation mode. Hob lighting I ^ The hob lighting can be switched on and off independently of the fan by pressing the hob lighting control I.
Cleaning and care A range of Miele branded cleaning and conditioning products is available to order from Miele (see back page for details) or the via the internet at www.miele-shop.com. Before any cleaning or maintenance work is carried out, disconnect the cooker hood from the mains supply.
Cleaning and care Controls The controls may suffer discolouration or damage if soiling is left on them for too long. Remove soiling straight away. ^ Observe the General notes on cleaning earlier in this section. Do not use stainless steel cleaning agents on the controls. Grease filters The re-usable metal grease filters in the appliance remove solid particles (grease, dust, etc.) from the kitchen vapours, preventing soiling of the cooker hood.
Cleaning and care Cleaning the grease filters by hand ^ Clean the filters with a soft nylon brush in a mild solution of hot water and a little washing-up liquid. Do not use "neat" washing up liquid. Do not use: – cleaning agents containing descaling agents, ^ When removing the filters for cleaning, also clean off any residues of oil or fat from the now accessible housing to prevent the risk of these catching fire.
Cleaning and care Fitting and replacing the charcoal filter If the cooker hood is connected for recirculation, a charcoal filter must be inserted in addition to the grease filters. This is designed to absorb cooking odours. It is fitted in the canopy above the grease filters. New charcoal filters can be purchased from your Miele dealer, from the Miele Spare Parts Department or via the internet at www.miele.shop.com. See back cover for contact details, and "Technical data" for the model number of the filter.
Cleaning and care Changing a halogen lamp ^ Before any cleaning or maintenance work, disconnect the cooker hood from the mains supply. Ensure that: – it is switched off at the isolator, or – it is switched off at the wall socket and the plug is withdrawn, or – the fuse from the fused spur connection unit is withdrawn, or – the mains fuse is disconnected, or – the screw-out fuse is removed (in countries where this is applicable). ,Exercise caution when changing halogen lamps.
Appliance dimensions The diagram is not drawn to scale.
Appliance dimensions a Extraction b Recirculation c Ventilation grille positioned at the top for recirculation d, e (e is not required for recirculation mode cooker hoods).The shaded areas represent the wall or ceiling area for the vent cut-out and for fitting the connection socket. For recirculation mode, only a connection socket needs to be fitted. Connection for air extraction C 150 mm, or C 125 mm with reducing collar.
Appliance dimensions Drilling diagram This diagram illustrates where holes for Ø 5 mm screws need to be drilled in the rear wall. * The dimensions between the ceiling and the middle bracket can vary depending on the position of the vent cut-out and the connection socket. It should be installed as low as possible. If the cooker hood is being secured directly to the wall, please follow the drilling instructions given in the installation instructions supplied.
Installation Dismantling Before installation, it is important to read the information given on the following pages as well as the "Appliance dimensions" and the "Warning and Safety instructions" at the beginning of this booklet. This is particularly crucial when using the cooker hood at the same time as a heating appliance that relies on oxygen from the same room to avoid the danger of toxic fumes building up.
Installation Assembly parts 24
Installation a 3 protective sheets for use when fitting the tower. b 1 exhaust connection for exhaust ducting C 150 mm. c 1 reducing collar for exhaust ducting C 125 mm. d 1 non-return valve for fitting into the exhaust connection on the motor unit (not for recirculation mode). e Upper wall bracket for securing the extension piece. 8 screws 5 x 40 mm and 8 x S 8 plugs for securing the retaining plates to the wall. The screws and plugs are designed for use in solid walls.
Connection for air extraction Important: To avoid the danger of toxic fumes, please observe the Warning and Safety instructions. This is especially crucial when using the cooker hood at the same time as another heating appliance which relies on air from the same room. The cooker hood should be installed according to local and national building regulations. Seek approval from the building inspector where necessary. – Where ducting is horizontal, it must be laid to slope away at at least 1 cm per metre.
Connection for air extraction Condensate trap (optional accessory) In addition to insulating the exhaust ducting, we recommend that a suitable condensate trap is also installed to collect and evaporate any condensate which may occur. Condensate traps are available for C 125 mm or C 150 mm ducting. When installing a condensate trap, ensure that it is positioned vertically and if possible directly above the exhaust connection. The arrow on the housing indicates the direction of air-flow.
Connection for air extraction Silencer (optional accessory) ...with air extraction: To achieve even further reductions in noise levels, a special silencer can be fitted in the ducting system. The silencer not only reduces noise from the motor, but also sounds from outside (e.g. traffic noise). For this reason the silencer must be positioned as close as possible to where the ducting leaves the building a. ...in recirculation mode: The silencer needs to be positioned between the motor and the deflector b.
Electrical connection All electrical work should be undertaken by a suitably qualified and competent person in strict accordance with current national and local safety regulations (BS 7671 in the UK). Installation, repairs and other work by unqualified persons could be dangerous, for which the manufacturer cannot be held liable. Ensure power is not supplied to the appliance until after installation or repair work has been carried out.
Operation with Control module DSM 400 The Miele DSM 400 Control module can be used to combine the cooker hood with other components. It enables the following: Connection to a window contact switch If adequate ventilation to the room can only be ensured by having a window open when the cooker hood is in use at the same time as a heating appliance which depends on the air from the same room, then the control module can be used to connect a window contact switch (not supplied) to the appliance.
Operation with Control module DSM 400 Connection to a light switch The control module can be used to switch on the cooker hood lighting via a light switch in the house. Installation The tower needs to be removed before the control module can be fitted to the fan unit. The control module is supplied with its own detailed operating and installation instructions.
After Sales Service In the event of a fault which you cannot correct yourself, or if the appliance is under guarantee, please contact: – Your Miele Dealer / Chartered Agent or – The Miele Service Department (see back cover for address). When contacting your Dealer or Miele, please quote the model and serial number of your appliance. These are shown on the data plate which is visible when the grease filter is removed. For G.B.
Technical data Total connected load DA 416-4 . . . . . . . . . . . . . . . . . . . 160 W DA 419-4 . . . . . . . . . . . . . . . . . . . 180 W - Fan motor . . . . . . . . . . . . . . . . . 120 W - Hob lighting DA 416-4 . . . . . . . . . . . . . . . . . 2 x 20 W DA 419-4 . . . . . . . . . . . . . . . . . 3 x 20 W Voltage . . . . . . . . . . . . . . . . . . . . 230 V Frequency . . . . . . . . . . . . . . . . . . 50 Hz Fuse rating (UK) . . . . . . . . . . . . . . . . 5 A Electrical cable length . . . . . . . .
Alteration rights reserved / 2910 M.-Nr.