Installation and Operation Guide
Table Of Contents
- Contents
- Warning and Safety instructions
- Caring for the environment
- Overview
- Cleaning the SmartLine appliance for the first time
- Description of the functions
- Tips on saving energy
- Operation
- Cleaning and care
- Problem solving guide
- Optional accessories
- Service
- Installation
- Safety instructions for installation
- Installation examples
- Surface-mounted
- Installation notes – surface-mounted
- Worktop cut-out – surface-mounted
- Spacer bars – surface-mounted
- Spacer bars for the downdraft extractor – surface-mounted
- Installation dimensions – Surface-mounted
- Air duct dimensions – surface-mounted – worktop depth 600 mm
- Air duct dimensions – surface-mounted – worktop depth greater than 600 mm
- Installation – surface-mounted
- Flush-fit
- Installation notes – flush-fit
- Worktop cut-out – flush-fit
- Spacer bars – flush-fit
- Spacer bars for the downdraft extractor – flush-fit
- Installation dimensions – Flush
- Air duct dimensions – flush-fit – worktop depth 600 mm
- Air duct dimensions – flush-fit – worktop depth greater than 600 mm
- Installation – flush-fit
- Exhaust ducting
- Electrical connection
Installation
*INSTALLATION*
63
E-box
a
Mains connection cable
b
Connection to window contact
c
Connection socket for the fan power
cable
d
Connection socket for the fan
control cable
e
Connection socket for the control
unit cable
Connection to window contact, if
required
The window contact is
connected to the mains voltage.
Danger of electric shock!
Disconnect the downdraft extractor
from the mains electricity supply
before connecting the switching
system.
The connection cable of the
switching system must only be
connected by a suitably qualified and
competent electrician.
The connection cable of the
switching system must be of the
correct type and cross-sectional area
in strict accordance with current
national and local safety regulations
and must not exceed 2.0m in length.
The switching system must be
equipped with a potential-free
contact suitable for 230V, 1A. The
extractor is switched off when the
switch is open.
Only use suitable switching systems
(e.g. window contact switches,
pressure switches).
The switching system must be
suitable for use with inductive loads
(BLDC motor).
Use switching systems in strict
accordance with current national and
local safety regulations.