Operating instructions/Installation instructions
Table Of Contents
- Contents
- Warning and Safety instructions
- Caring for the environment
- Guide to the appliance
- How it works
- Cleaning the SmartLine element for the first time
- Operation
- Tips on saving energy
- Cleaning and care
- Problem solving guide
- Optional accessories
- After sales service
- Installation
- Safety instructions for installation
- Installation examples
- Installation notes – surface-mounted
- Worktop cutout – surface-mounted
- Spacer bars – surface-mounted
- Spacer bars for the downdraft extractor – surface-mounted
- Installation dimensions – Surface-mounted
- Air duct dimensions – surface-mounted – worktop depth 600 mm
- Air duct dimensions – surface-mounted – worktop depth greater than 600 mm
- Installation – surface-mounted
- Securing the brackets
- Wooden worktops
- Natural stone worktops
- Preparing the worktop
- Fitting the spacer bars
- Wooden worktops
- Natural stone worktops
- Installing the countertop extractor
- Installing the air duct
- Length compensation
- Length compensation – worktop depth 600 mm
- Length compensation – worktop depth greater than 600 mm
- Installing the fan motor
- E-box
- Connection to window contact, if required
- Connecting the e-box
- Sealing the gaps
- Installation notes – flush-fit
- Worktop cutout – flush-fit
- Spacer bars – flush-fit
- Spacer bars for the downdraft extractor – flush-fit
- Installation dimensions – Flush-fit
- Air duct dimensions – flush-fit – worktop depth 600 mm
- Air duct dimensions – flush-fit – worktop depth greater than 600 mm
- Installation – flush-fit
- Securing the brackets
- Wooden worktops
- Natural stone worktops
- Preparing the worktop
- Fitting the spacer bars
- Wooden worktops
- Natural stone worktops
- Installing the countertop extractor
- Installing the air duct
- Length compensation
- Length compensation – worktop depth 600 mm
- Length compensation – worktop depth greater than 600 mm
- Installing the fan motor
- E-box
- Connection to window contact, if required
- Connecting the e-box
- Sealing the gaps
- Ducting
- Electrical connection
- Product data sheets
Installation
*INSTALLATION*
67
Preparing the worktop
Create the worktop cutout. Remem-
ber to maintain the minimum safety
distances (see “Installation – Safety
distances”).
Seal any cut surfaces on wooden
worktops with a special varnish, sil-
icone sealant or resin to prevent the
wood from swelling as a result of
moisture ingress. The sealant must
be heat-resistant.
Make sure that the sealant does not
come into contact with the top of the
worktop.
For wooden worktops, secure the
wooden frame 5.5mm below the up-
per edge of the worktop.
For CS7611FL, the wooden frame
must be secured 7mm under the up-
per edge of the worktop.
Fitting the spacer bars
Use the middle screw holes if one of the
following SmartLine elements is in-
stalled to the right or left of the spacer
bar: CS7611, CS 7641, CS7101(-1),
CS7102(-1)
Wooden worktops
Position the spacer bars flush onto
the lower step of the stepped cutout.
Secure the spacer bars with the
3.5x25mm wood screws supplied.
Natural stone worktops
You will need heavy-duty double-
sided tape (not supplied) to secure the
spacer bars.
Stick the tape onto the lower step of
the stepped cutout.
Position the spacer bars flush onto
the lower step of the stepped cutout.
Press the spacer bars firmly into
place.