Operating instructions/Installation instructions
Table Of Contents
- Contents
- Warning and Safety instructions
- Caring for the environment
- Guide to the appliance
- How it works
- Cleaning the SmartLine element for the first time
- Operation
- Tips on saving energy
- Cleaning and care
- Problem solving guide
- Optional accessories
- After sales service
- Installation
- Safety instructions for installation
- Installation examples
- Installation notes – surface-mounted
- Worktop cutout – surface-mounted
- Spacer bars – surface-mounted
- Spacer bars for the downdraft extractor – surface-mounted
- Installation dimensions – Surface-mounted
- Air duct dimensions – surface-mounted – worktop depth 600 mm
- Air duct dimensions – surface-mounted – worktop depth greater than 600 mm
- Installation – surface-mounted
- Securing the brackets
- Wooden worktops
- Natural stone worktops
- Preparing the worktop
- Fitting the spacer bars
- Wooden worktops
- Natural stone worktops
- Installing the countertop extractor
- Installing the air duct
- Length compensation
- Length compensation – worktop depth 600 mm
- Length compensation – worktop depth greater than 600 mm
- Installing the fan motor
- E-box
- Connection to window contact, if required
- Connecting the e-box
- Sealing the gaps
- Installation notes – flush-fit
- Worktop cutout – flush-fit
- Spacer bars – flush-fit
- Spacer bars for the downdraft extractor – flush-fit
- Installation dimensions – Flush-fit
- Air duct dimensions – flush-fit – worktop depth 600 mm
- Air duct dimensions – flush-fit – worktop depth greater than 600 mm
- Installation – flush-fit
- Securing the brackets
- Wooden worktops
- Natural stone worktops
- Preparing the worktop
- Fitting the spacer bars
- Wooden worktops
- Natural stone worktops
- Installing the countertop extractor
- Installing the air duct
- Length compensation
- Length compensation – worktop depth 600 mm
- Length compensation – worktop depth greater than 600 mm
- Installing the fan motor
- E-box
- Connection to window contact, if required
- Connecting the e-box
- Sealing the gaps
- Ducting
- Electrical connection
- Product data sheets
Installation
*INSTALLATION*
66
Installation – flush-fit
If the worktop is more than 28mm
deep, it must be cut out underneath
on the building-in side on the right or
left hand side.
a
Worktop
b
Maximum 24mm
c
12mm
Securing the brackets
1bracket (supplied with the spacer bar)
must be secured centrally to the right or
left-hand side of the cutout.
Wooden worktops
Fit the bracket so that it sits flush
with the top edge of the lower step of
the stepped cutout.
Secure the bracket with the
3.5x25mm wood screws supplied.
Natural stone worktops
You will need heavy-duty double-
sided tape (not supplied) to secure the
bracket.
Stick the tape onto the upper edge of
the lower step of the stepped cutout.
Fit the bracket so that it sits flush
with the top edge of the lower step of
the stepped cutout.
Press the bracket firmly into position.