Operating instructions/Installation instructions
Table Of Contents
- Contents
- Warning and Safety instructions
- Caring for the environment
- Guide to the appliance
- How it works
- Cleaning the SmartLine element for the first time
- Operation
- Tips on saving energy
- Cleaning and care
- Problem solving guide
- Optional accessories
- After sales service
- Installation
- Safety instructions for installation
- Installation examples
- Installation notes – surface-mounted
- Worktop cutout – surface-mounted
- Spacer bars – surface-mounted
- Spacer bars for the downdraft extractor – surface-mounted
- Installation dimensions – Surface-mounted
- Air duct dimensions – surface-mounted – worktop depth 600 mm
- Air duct dimensions – surface-mounted – worktop depth greater than 600 mm
- Installation – surface-mounted
- Securing the brackets
- Wooden worktops
- Natural stone worktops
- Preparing the worktop
- Fitting the spacer bars
- Wooden worktops
- Natural stone worktops
- Installing the countertop extractor
- Installing the air duct
- Length compensation
- Length compensation – worktop depth 600 mm
- Length compensation – worktop depth greater than 600 mm
- Installing the fan motor
- E-box
- Connection to window contact, if required
- Connecting the e-box
- Sealing the gaps
- Installation notes – flush-fit
- Worktop cutout – flush-fit
- Spacer bars – flush-fit
- Spacer bars for the downdraft extractor – flush-fit
- Installation dimensions – Flush-fit
- Air duct dimensions – flush-fit – worktop depth 600 mm
- Air duct dimensions – flush-fit – worktop depth greater than 600 mm
- Installation – flush-fit
- Securing the brackets
- Wooden worktops
- Natural stone worktops
- Preparing the worktop
- Fitting the spacer bars
- Wooden worktops
- Natural stone worktops
- Installing the countertop extractor
- Installing the air duct
- Length compensation
- Length compensation – worktop depth 600 mm
- Length compensation – worktop depth greater than 600 mm
- Installing the fan motor
- E-box
- Connection to window contact, if required
- Connecting the e-box
- Sealing the gaps
- Ducting
- Electrical connection
- Product data sheets
Installation
*INSTALLATION*
50
E-box
a
Mains connection cable
b
Connection to window contact
c
Electrical connection socket for the
fan operating voltage cable
d
Electrical connection socket for the
fan control cable
e
Electrical connection socket for the
control unit cable
Connection to window contact, if re-
quired
The window contact connection
is live!
Danger of electric shock!
Disconnect the countertop extractor
from the mains before connecting
the switching system.
The connection cable of the switch-
ing system must only be connected
by a suitably qualified and compet-
ent electrician.
The connection cable of the switch-
ing system must comply with type
H03VV-F 2x0.75mm
2
and must not
exceed 2.0m in length.
The switching system must be
equipped with a potential-free con-
tact suitable for 230V, 1A. The ex-
tractor is switched off when the
switch is open.
Only use DIPT-approved and tested
radio switching systems (e.g. window
contact switches, pressure switches)
and have them approved by author-
ised specialists (e.g. building regula-
tions inspector).
The switching system must be suit-
able for use with a BLDC motor.
You will need the appropriate ex-
ternal switching system documents
to safely connect and operate the
switch.