Operating instructions/Installation instructions
Table Of Contents
- Contents
- Warning and Safety instructions
- Caring for the environment
- Guide to the appliance
- How it works
- Cleaning the SmartLine element for the first time
- Operation
- Tips on saving energy
- Cleaning and care
- Problem solving guide
- Optional accessories
- After sales service
- Installation
- Safety instructions for installation
- Installation examples
- Installation notes – surface-mounted
- Worktop cutout – surface-mounted
- Spacer bars – surface-mounted
- Spacer bars for the downdraft extractor – surface-mounted
- Installation dimensions – Surface-mounted
- Air duct dimensions – surface-mounted – worktop depth 600 mm
- Air duct dimensions – surface-mounted – worktop depth greater than 600 mm
- Installation – surface-mounted
- Securing the brackets
- Wooden worktops
- Natural stone worktops
- Preparing the worktop
- Fitting the spacer bars
- Wooden worktops
- Natural stone worktops
- Installing the countertop extractor
- Installing the air duct
- Length compensation
- Length compensation – worktop depth 600 mm
- Length compensation – worktop depth greater than 600 mm
- Installing the fan motor
- E-box
- Connection to window contact, if required
- Connecting the e-box
- Sealing the gaps
- Installation notes – flush-fit
- Worktop cutout – flush-fit
- Spacer bars – flush-fit
- Spacer bars for the downdraft extractor – flush-fit
- Installation dimensions – Flush-fit
- Air duct dimensions – flush-fit – worktop depth 600 mm
- Air duct dimensions – flush-fit – worktop depth greater than 600 mm
- Installation – flush-fit
- Securing the brackets
- Wooden worktops
- Natural stone worktops
- Preparing the worktop
- Fitting the spacer bars
- Wooden worktops
- Natural stone worktops
- Installing the countertop extractor
- Installing the air duct
- Length compensation
- Length compensation – worktop depth 600 mm
- Length compensation – worktop depth greater than 600 mm
- Installing the fan motor
- E-box
- Connection to window contact, if required
- Connecting the e-box
- Sealing the gaps
- Ducting
- Electrical connection
- Product data sheets
Cleaning and care
24
Grease filter/extraction grille
The extraction grille and the reusable
metal grease filter in the vapour extrac-
tion fan collect solid matter from kit-
chen vapours (grease, dust, etc.) and
therefore prevent soiling of the
downdraft extractor. Accumulated
grease solidifies over a longer period of
time and makes cleaning more difficult.
The grease filter should therefore be
cleaned at least every 3–4weeks.
Risk of fire due to soiled grease
filter.
Grease collected in the grease filter
can ignite.
Clean the grease filter regularly.
Removing the grease filter
Remove the FlameGuard if neces-
sary.
Lift up the extraction grille.
Carefully remove the grease filter. En-
sure that you do not tilt the grease fil-
ter.
Pour out any liquid which has collec-
ted at the bottom of the grease filter.
Cleaning the extraction grille and the
grease filter by hand
Clean the extraction grille and the
grease filter with a soft nylon brush in
a mild solution of hot water and a
little washing-up liquid. Do not use
concentrated washing-up liquid.
Cleaning the extraction grille and the
grease filter in the dishwasher
Place the extraction grille upright in
the lower basket.
Place the grease filter with its base
facing upwards in the lower basket.
Ensure the spray arm is not obstruc-
ted.
Use a standard household dish-
washer detergent.
Select a dishwasher programme with
a maximum wash temperature of:
- 55°C for the extraction grille
- 65°C for the grease filter
Depending on the detergent used,
cleaning the grease filter in a dish-
washer can cause permanent discol-
ouration to the internal surfaces of the
filter. However, this will not affect the
functioning of the grease filter in any
way.