Operating instructions/Installation instructions
Table Of Contents
- Contents
- Warning and Safety instructions
- Caring for the environment
- Guide to the appliance
- How it works
- Cleaning the SmartLine element for the first time
- Operation
- Tips on saving energy
- Cleaning and care
- Problem solving guide
- Optional accessories
- After sales service
- Installation
- Safety instructions for installation
- Installation examples
- Installation notes – surface-mounted
- Worktop cutout – surface-mounted
- Spacer bars – surface-mounted
- Spacer bars for the downdraft extractor – surface-mounted
- Installation dimensions – Surface-mounted
- Air duct dimensions – surface-mounted – worktop depth 600 mm
- Air duct dimensions – surface-mounted – worktop depth greater than 600 mm
- Installation – surface-mounted
- Securing the brackets
- Wooden worktops
- Natural stone worktops
- Preparing the worktop
- Fitting the spacer bars
- Wooden worktops
- Natural stone worktops
- Installing the countertop extractor
- Installing the air duct
- Length compensation
- Length compensation – worktop depth 600 mm
- Length compensation – worktop depth greater than 600 mm
- Installing the fan motor
- E-box
- Connection to window contact, if required
- Connecting the e-box
- Sealing the gaps
- Installation notes – flush-fit
- Worktop cutout – flush-fit
- Spacer bars – flush-fit
- Spacer bars for the downdraft extractor – flush-fit
- Installation dimensions – Flush-fit
- Air duct dimensions – flush-fit – worktop depth 600 mm
- Air duct dimensions – flush-fit – worktop depth greater than 600 mm
- Installation – flush-fit
- Securing the brackets
- Wooden worktops
- Natural stone worktops
- Preparing the worktop
- Fitting the spacer bars
- Wooden worktops
- Natural stone worktops
- Installing the countertop extractor
- Installing the air duct
- Length compensation
- Length compensation – worktop depth 600 mm
- Length compensation – worktop depth greater than 600 mm
- Installing the fan motor
- E-box
- Connection to window contact, if required
- Connecting the e-box
- Sealing the gaps
- Ducting
- Electrical connection
- Product data sheets
Warning and Safety instructions
11
In order to ensure safe operation and to prevent gases given off by
the heating appliance from being drawn back into the room, when
the downdraft extractor and the heater are both operated simultan-
eously, an underpressure in the room of 0.04mbar (4Pa) is the
maximum permissible.
Sufficient ventilation can be maintained by air inlets which cannot
be blocked, e.g. in windows, doors and outside wall vents. The
diameter of the inlet openings must enable sufficient ventilation. A
ventilation brick alone is not generally sufficient to ensure safe
ventilation.
The overall ventilation condition of the dwelling must be taken into
account. If in any doubt, the advice of a competent builder, or for
gas, a qualified gas fitter should be sought.
If the downdraft extractor is being operated in recirculation mode,
where the air is directed back into the room in which it is located,
operating a heating appliance which depends on the room air at
the same time is not hazardous.