Operation Manual

Installation notes
28
Installing several SmartLine
elements
The gaps between the individual Smart-
Line elements are sealed with a silicone
sealant that is heat-resistant to at least
160°C. With flush-fit installation, the
gap between the SmartLine element(s)
and the worktop must also be sealed
with a silicone sealant that is heat-res-
istant to at least 160°C.
After installation, the SmartLine ele-
ments must be easily accessible from
below, so that the bottom half of the
casing can be removed for mainten-
ance. If the SmartLine elements are not
accessible from below, the sealant must
be removed so that they can be re-
moved.
Minimum plinth height
The downdraft extractor fan is installed
in the plinth below the cabinet floor. The
minimum plinth height must be
100mm.
Worktop depth
The downdraft extractor can be in-
stalled with the connector for the air
duct on either the right or the left side.
Minimum worktop depth for
right connector 600mm
left connector 665mm
Housing unit back panel
The extraction ducting is laid behind the
housing unit back panel. The back
panel must be removable for mainten-
ance purposes.
Grease trap
The downdraft extractor must be in-
stalled in such a way that the grease
trap is freely accessible and can be re-
moved for cleaning.