Installation and Operation Guide
Table Of Contents
- Contents
- Warning and Safety instructions
- Caring for the environment
- Overview
- Before using for the first time
- Suitable cookware
- Tips on saving energy
- Operation
- Safety features
- Cleaning and care
- Problem solving guide
- Optional accessories
- Service
- Installation
- Safety instructions for installation
- Safety distances
- Detailed dimensions
- Surface-mounted
- Installation notes – surface-mounted
- Worktop cut-out – surface-mounted
- Spacer bars – surface-mounted
- Installation dimensions – Surface-mounted
- Installation – surface-mounted
- Flush-fit
- Installation notes – flush-fit
- Worktop cut-out – flush-fit
- Spacer bars – flush-fit
- Installation dimensions – Flush
- Installation – flush-fit
- Gas connection
- Electrical connection
- Burner ratings
- Conversion to another type of gas
Installation
*INSTALLATION*
43
Worktop cut-out – surface-mounted
B
500
+1
ß
R 4
B
10
0
10
Information for calculating the cut-out
The appliances overlap the worktop by 10mm.
When installing several appliances, a distance of 2mm must be observed between
the individual appliances.
Calculating cut-out dimensionB
1 appliance = width of the appliance minus 10mm on the right, minus 10mm on
the left
Several appliances = total width of the appliances plus 2mm distance between
the appliances, minus 10mm on the right, minus 10mm on the left.
Some examples are illustrated below.