dimension guide

Product and Cut-out Dimensions Page 4 of 5
CS 1322 BG Electric Barbecue CombiSet
1 Wall frame
2 Wall covering
x = thickness of the wall covering
3
Countertop
Safety distances to back wall
CS
1322
BG
Electric
Barbecue
CombiSet
If a wall covering is installed, a minimum safety distance must be maintained between the countertop cut-out
and the covering, since high temperatures can damage these materials.
3
Countertop
4 – Countertop cut-out
5 – Minimum safety distance
with flammable materials 2" (50 mm)
with non-flammable materials 2" (50 mm) minus x
If the covering is made of a combustible material (such as wood), the distance between the countertop cut-out
and the wall covering must be a minimum of 2" (50 mm).
For coverings made of non-combustible materials (such as metal, marble, granite or ceramic tiles) the
minimum safety distance between the countertop cut-out and the wall covering must be 2" (50 mm) minus the
thickness of the covering.
For example: thickness of wall covering 9/16" (15 mm) 2" (50 mm) - 9/16" (15 mm) = minimum safety distance
1 3/8" (35 mm).
Safety distances to surrounding cabinetry
Recommended Not Recommended Not Permitted
The appliance should only be installed as shown in the above illustrations while maintaining the
required safety distances shown. Do not install the appliance between two tall cabinets, this is a
fire hazard
fire
hazard
.
A distance of at least 2” (50 mm) must be kept between the countertop and the rear wall
because of high temperature radiated.
The minimum distance required from the countertop cut-out to a side wall or tall cabinet right or
left 8” (200 mm) (Location code 1)
Notes
All installations must be done in accordance with local codes.
Drawing is not to scale Specification Sheets OJS
02212012