Safety distances to the sides
of the appliance
The appliance should only be installed
as shown in the illustrations, while
maintaining the required safety
distances shown. Do not install the
appliance between two tall cabinets,
this is a fire hazard.
A distance of at least 2" (50 mm) must
be kept between the countertop cut-out
and the rear wall because of the high
temperatures radiated.
The minimum distance required from
the countertop cut-out to the side wall
a:
2" (50 mm) for CS 1112
CS 1122
CS 1212
CS 1221
CS 1223
CS 1326
CS 1411
6" (150 mm) for CS 1312
CS 1322
CS 1421
10" (250 mm) for CS 1011
CS 1012
CS 1028
recommended
not recommended
not allowed
IMPORTANT SAFETY INSTRUCTIONS
24
2 "
(50 mm)
(50mm)
1
2"