Operating instructions/Installation instructions
Table Of Contents
- Contents
- Warning and Safety instructions
- Caring for the environment
- Guide to the appliance
- How it works
- Before using for the first time
- Operation
- Setting ranges
- Timer
- Additional functions
- Safety features
- Programming
- Cleaning and care
- Problem solving guide
- Optional accessories
- After sales service
- Installation
- Safety instructions for installation
- Safety distances
- Installation notes – surface-mounted
- Worktop cutout – surface-mounted
- Spacer bars – surface-mounted
- Installation dimensions – Surface-mounted
- Installation – surface-mounted
- Installation notes – flush-fit
- Worktop cutout – flush-fit
- Spacer bars – flush-fit
- Installation dimensions – Flush-fit
- Installation – flush-fit
- Electrical connection
Installation
*INSTALLATION*
47
Minimum safety distance underneath
the SmartLine element
To ensure proper ventilation of the
SmartLine element, a minimum safety
distance is required between the ele-
ment and an oven, interim shelf or
drawer.
The minimum safety distance from the
lower edge of the SmartLine element to
- Upper edge of oven: 15mm
- Upper edge of interim shelf: 15mm
- Upper edge of drawer: 5mm
- Base of drawer: 75mm
Intermediate shelf
It is not necessary to fit an interim shelf
underneath the SmartLine element but
one may be fitted if you wish.
Leave a gap of 10mm at the back of
the shelf to accommodate the mains
connection cable. We recommend a
gap at the front of the SmartLine ele-
ment of 20mm to ensure good ventila-
tion.