Operating instructions/Installation instructions
Table Of Contents
- Contents
- Warning and Safety instructions
- Caring for the environment
- Guide to the appliance
- How it works
- Pans
- Before using for the first time
- Operation
- Setting range
- Tips on saving energy
- Timer
- Additional functions
- Safety features
- Programming
- Note for test institutes
- Cleaning and care
- Problem solving guide
- Optional accessories
- After sales service
- Installation
- Safety instructions for installation
- Safety distances
- Installation notes – surface-mounted
- Worktop cutout – surface-mounted
- Spacer bars – surface-mounted
- Installation dimensions – Surface-mounted
- Installation – surface-mounted
- Installation notes – flush-fit
- Worktop cutout – flush-fit
- Spacer bars – flush-fit
- Installation dimensions – Flush-fit
- Installation – flush-fit
- Electrical connection
- Product data sheets
How it works
20
Power management
The hob has a maximum total permitted
power consumption which cannot be
exceeded for safety reasons.
The two cooking zones on the hob are
interconnected. This allows additional
power to be transferred from one cook-
ing zone to another.
The previously set setting has preced-
ence and the hob will operate with this
level.
If power is transferred from one cooking
zone to the linked cooking zone, the
power for the first cooking zone must
be reduced.
The possible values for the maximum
total permitted power consumption
can be found in “Overview – Cooking
zone data”.
If the new cooking zone requires more
power than the first cooking zone can
provide, this may result in the following
consequences for the first cooking
zone:
- The power level is reduced.
- Auto heat-up will be deactivated.
Cooking continues at the set level. If
the power is not sufficient, the power
level will be reduced again.
- The Booster function is deactivated.
- The cooking zone is switched off.
If the most recently set power level is
reduced or the Booster function is
switched off, the power level for the
linked cooking zone can be increased
again.