Operating instructions/Installation instructions
Converting to another gas type
*INSTALLATION*
64
Risk of explosion due to an in-
correct conversion.
If the conversion to another type of
gas is carried out incorrectly, it may
result in gas leakage.
Conversion from one type of gas to
another must only be undertaken by
an approved and registered gas in-
staller in strict accordance with cur-
rent local and national safety and
building regulations (GasSafe in the
UK). The installer is responsible for
ensuring that the appliance functions
correctly when installed.
Jet table
The jet markings refer to a ¹/₁₀₀mm
bore diameter.
Main jet Small jet
Natural gas H
Medium burner 0.94 0.42
Large burner 1.18 0.54
Liquid gas
Medium burner 0.66 0.23
Large burner 0.81 0.39
Changing the jets
Disconnect the hob from the electri-
city supply and turn off the gas sup-
ply.
When converting to another type of
gas, both the main and small jets
need to be changed.
Changing the main jets
Remove the pot rest, burner cap
and burner head.
Using an M7 socket spanner, un-
screw the main jet.
Fit the correct jets securely (see jet
table).
Secure the jets against inadvertent
loosening with sealing wax.