Installation Instructions
Table Of Contents
- Contents
- Guide to the appliance 4
- Warning and Safety instructions 9
- Caring for the environment 16
- Before using for the first time 17
- Induction 18
- Operation 21
- Tips on saving energy 27
- Safety features 28
- Cleaning and care 30
- Problem solving guide 32
- Optional accessories 34
- Safety instructions for installation 35
- Appliance and building-in dimensions 39
- Preparing the worktop 42
- Installation of several appliances 43
- Fixing the spring clamps and spacer bars 45
- Installing the appliance(s) 47
- General installation tips 48
- Electrical connection 49
- After sales service, data plate 52

Booster function
The cooking zones are equipped with
Single (l) or Twin Boosters (I/II) (see
"Guide to the appliance").
When activated, the power is boosted
so that large quantities can be heated
quickly, e.g. boiling water for cooking
pasta. When Booster l or Booster ll is
activated, the cooking zones will
operate with extra power for
10 minutes.
The booster function cannot be used
with two cooking zones at the same
time.
Exception: On the CS 1234, the booster
function can be used with one of the
cooking zones on the left and with one
on the right at the same time.
The cooking zone will automatically
revert to power setting 9 at the end of
the booster time.
Taking a pan off the zone whilst the
booster is in operation interrupts the
booster function. It will resume if a pan
is placed back on the zone within 3
minutes.
The extra boost of energy is only
available by taking a proportion of
energy away from another cooking
zone. For this reason, the cooking
zones are networked in pairs.
Example:
When selecting the Booster/Twin
Booster level l for a zone, the following
happens within the pairs:
–
If Auto heat-up is activated on the
other zone within the pair, this will be
switched off.
– If the other zone within the pair is set
at power setting 9, the power setting
on that zone will be reduced. The
reduced power setting will flash
alternately with C in the display.
If Twin Booster level ll is selected, the
other zone within the networked pair will
be switched off.
0 will flash alternately wtih C in the
display.
Operation
24