Datasheet

14
DA 2900 ceiling extractor
Product overview
DESIGN
Ceiling extractor
For installation in a suspended ceiling or a
conversion
Width: 110 cm
OPERATION MODES
Vented mode
Recirculation mode with optional extras possible
(recirculation box)
OPERATION
Light-touch switches with LEDs for hob lighting, On/
Off and power settings, operating hour counter for
grease and active coal filter saturation
(customisable), fan run-on (5/15 mins.),
programmable Intensive switch-back after 10 mins.,
three power settings plus Intensive, remote
operation also possible (standard accessory)
FEATURES
4 dishwasher-proof 10-ply stainless steel grease
filter, dishwasher-proof glass or stainless steel
edge-extraction panels as optional extras
selectable,
CleanCover for simple cleaning of machine interior,
LED lighting 4 x 2 W, electronic power controls, two-
point suction, DC motor for highest possible energy
efficiencies, Power Management System, non-
return baffle, vent connection 150/125 mm Ø,
recommended connection: vent connection 150 mm
Ø, vertical exhaust connection or to the side in all
directions, insulation mats inside unit
SAFETY
Safety switch-off
FAN PERFORMANCE
Vented mode 150 mm  according to EN 61591
Int. XX m³/h, XX dB(A) re 1 pW (XX dB(A) re
20 µPa sound pressure)
Max. XX m³/h, XX dB(A) re 1 pW (XX dB(A) re
20 µPa sound pressure)
Vented mode 125 mm  according to EN 61591
Int. XX m³/h, XX dB(A) re 1 pW (XX dB(A) re
20 µPa sound pressure)
Max. XX m³/h, XX dB(A) re 1 pW (XX dB(A) re
20 µPa sound pressure)
Recirculation mode 150 mm according to
EN 61591
Int. XX m³/h, XX dB(A) re 1 pW (XX dB(A) re
20 µPa sound pressure)
Max. XX m³/h, XX dB(A) re 1 pW (XX dB(A) re
20 µPa sound pressure)
STANDARD ACCESSORIES
Remote control, reducing adapter for 125 mm Ø
OPTIONAL EXTRAS
DRP 2900 Glass edge-extraction panels , DRP
2900 stainless steel edge-extraction panels, DUU
2900 recirculation box, DSM 400 control module,
communication module for Con@ctivity XKM 2000
DA, DASD 150 silencer, DMK 150 wall vent, DDF
125/150 roof vent, DAS 150 vent hose
Customisation possible
FEATURES
As per DA 2900 but without fan motor, control lead
with plug (length: 1.85 m from control box to plug)
for connection of cooker hood to external fan
EXTERNAL FANS
MG 100, AWG 102, ABLG 202, DDG 102
OPTIONAL EXTRAS
DASD 150 silencer
DASDV 150 silencer connection
For decorative panelling for filter surfaces with glass
elements.
Dishwasher-proof glass edge-extraction panel set
for DA 2900 ceiling extractor, consisting of 4 panels.
For decorative panelling for filter surfaces with
stainless steel elements.
Dishwasher-proof glass edge-extraction panel set
for DA 2900 ceiling extractor, consisting of 4 panels.
DA 2900
ceiling extractor
DA 2900
external ceiling extractor
DRP 2900 glass
edge-extraction panels
DRP 2900 stainless steel
edge-extraction panels
DA 2900
ceiling extractor
1) Fan suction side
2) Swivel fan fitting, venting vertical or to the side in all
four directions
3) Fan unit freely locatable. Connection to extractor via
vent ducting and wiring.
4) Min. gap from adjacent wall of. 50 mm required.