Datasheet

INSTALLATION
For installation in an internal ceiling space, e.g. loft
FEATURES
Plastic coated, zinc plated steel casing
Double sided radial fan
Control cable with plug connectors for joining the
motor to the cooker hood
Connection stub 125/150 mm Ø
OUTPUT
Extraction = 280–900 m
3
/hr, unrestricted
In practice approx. 780 m
3
/hr *
Rated load 290 W
Voltage 230 V
Fuse rating 13 A
ACCESSORIES SUPPLIED
Additional 5 m long cable with plug connectors
OPTIONAL ACCESSORIES
Additional control cable, 6 m, 9 m and 12 m long
DASD 150 Silencer for 2–4 dB noise reduction.
500 x 200 mm for installation in a straight run of
ducting.
INSTALLATION ADVICE:
Make sure you position the motor in a safe,
but easily accessible location for servicing work and
that the extraction vapours cannot pose a nuisance.
* Measured with 90° elbow and 4 m ducting to the
external motor
ABLG 202 is available to special order only
INSTALLATION
For installation on a tiled roof (any angle)
N.B. Not suitable for flat roofs
FEATURES
Stainless steel casing with lead skirting
Single sided radial fan
75 cm long control cable with plug connectors for
joining the motor to the cooker hood
Connection stub 125/150 mm Ø
OUTPUT
Extraction = 310–1000 m
3
/hr, unrestricted
In practice approx. 820 m
3
/hr *
Rated load 165 W
Voltage 230 V
Fuse rating 13 A
ACCESSORIES SUPPLIED
Additional 5 m long cable with plug connectors
OPTIONAL ACCESSORIES
Additional control cable, 6 m, 9 m and 12 m long
DASD 150 Silencer for 2–4 dB noise reduction.
500 x 200 mm for installation in a straight run of
ducting.
INSTALLATION ADVICE:
Make sure you position the motor in a safe,
but easily accessible location for servicing work and
that the extraction vapours cannot pose a nuisance.
* Measured with 90° elbow and 4 m ducting to the
external motor
DDG 102 is available to special order only
ABLG 202DDG 102
INSTALLATION
For installation on an outside wall
FEATURES
Stainless steel casing
Single sided radial fan
75 cm long control cable with plug connectors for
joining the motor to the cooker hood
Connection stub 125/150 mm Ø
OUTPUT
Extraction = 300–1000 m
3
/hr, unrestricted
In practice approx. 820 m
3
/hr *
Rated load 165 W
Voltage 230 V
Fuse rating 13 A
ACCESSORIES SUPPLIED
180 mm Ø wall ducting, extends to 450 mm long
Additional 3 m long cable with plug connectors
OPTIONAL ACCESSORIES
Additional control cable, 6 m, 9 m and 12 m long
DASD 150 Silencer for 2–4 dB noise reduction.
500 x 200 mm for installation in a straight run of
ducting.
INSTALLATION ADVICE:
Make sure you position the motor in a safe,
but easily accessible location for servicing work and
that the extraction vapours cannot pose a nuisance.
* Measured with 90° elbow and 4 m ducting to the
external motor
AWG 102 is available from stock
AWG 102
ABLG 202 and DDG 102
ba
AWG 102
a
External motors
b
98