Operating instructions/Installation instructions
Table Of Contents
- Contents
- Warning and Safety instructions
- Caring for the environment
- Installation
- Location
- Installation notes
- Building-in dimensions
- Dimensions of the furniture front
- Installing the appliance
- Before starting ...
- Tools required
- Weight of the furniture front
- Aligning the building-in niche
- Checking the building-in niche
- Before installation
- Preparing the building-in niche
- Pushing the refrigeration appliance into the building-in niche
- Aligning the refrigeration appliance
- Securing the refrigeration appliance in the building-in niche
- Preparing to install the furniture fronts
- Securing and aligning the furniture front
- Mounting the fixing bracket
- Securing the covers
- Installing the cover in a side-by-side combination
- Securing the plinth ventilation grille and plinth panel
- Limiting the opening angle of the appliance door
- Electrical connection
- Saving energy
- Guide to the appliance
- Accessories
- Initial commissioning
- Switching on and off
- Selecting additional settings
- The correct temperature
- Using Super cool
- Door alarm
- Adjusting the interior fittings
- Storing food in the refrigerator section
- Storing food in the MasterFresh zone
- Automatic defrosting
- Cleaning and care
- Problem solving guide
- Noises
- Service
- EU Conformity declaration
- UK Conformity declaration
- Copyrights and Licences
Installation
*INSTALLATION*
25
Weight of the furniture front
Before fitting a furniture front, ensure
that the weight of the furniture front
does not exceed the maximum permit-
ted weight:
Refrigeration appli-
ance
Max. weight
of the fur-
niture front
K2602Vi, K2612Vi 48kg
K2802Vi, K2812Vi 27kg
K2902Vi, K2912Vi 48kg
If the furniture front is too heavy,
this can cause damage.
Fitting a furniture front which is heav-
ier than the maximum permitted
weight could damage the hinges.
This damage can affect various
factors, such as operation of the ap-
pliance.
Before fitting a furniture front, ensure
that the weight of the furniture front
does not exceed the maximum per-
mitted weight.
Aligning the building-in niche
The building-in niche must be carefully
aligned using a spirit level before the re-
frigeration appliance is installed. The
niche corners must be at 90° angles to
each other, otherwise the furniture front
will not sit straight on all 4corners of
the building-in niche.