Operating and Installation instructions
Table Of Contents
- Contents
- IMPORTANT SAFETY INSTRUCTIONS
- Caring for the environment
- Saving energy
- Guide to the appliance
- Switching on and off
- The correct temperature
- Using SuperFrost
- Temperature and door alarm
- Selecting additional settings
- Freezing and storing food
- Adjusting the interior fittings
- Making ice cubes
- Automatic defrosting
- Cleaning and care
- Frequently asked questions
- Causes of noises
- Customer Service
- Information for dealers
- Installation
- Installation
- Installation dimensions
- Limiting the opening angle of the appliance door
- Changing the door hinges
- Building in the appliance
- Preparing the appliance
- With 5/8" (16 mm) thick cabinet walls only:
- Building in the appliance
- Securing the appliance in the niche
- Only for an appliance with a niche height greater than 55" (140 cm)
- Installing the cabinet door
- Adjusting the position of the door
- X: side adjustments
- Y: height adjustment
- Z: depth adjustment
- Water connection
- Electrical connection
Installation
*INSTALLATION*
90
The outlet must be easily accessible in
an emergency so that the appliance can
be quickly disconnected from the elec-
trical supply in case of an emergency.
The socket must be located so that the
upper edge is a maximum
82" (2100mm) distance from the upper
edge of the base of the kitchen cabinet.
If the outlet is no longer accessible
once the appliance has been installed,
an all-pole disconnect device with a
contact opening of at least 1/8" (3mm)
must be present on site. The discon-
nect device may be circuit breaker, a
fuse, or a contactor (compliant with lo-
cal regulations).
The plug and power cord must not
come into contact with the back of the
appliance as vibrations can cause dam-
age to these components. This, in turn,
could result in a short circuit.
Do not plug in other devices behind this
appliance.
Temporary or permanent operation on
an autonomous power supply system or
a power supply system that is not syn-
chronized with the grid power supply
(e.g., island networks, back-up sys-
tems) is possible. A prerequisite for op-
eration is that the power supply system
complies with the specifications of
EN50160 or an equivalent standard.
The function and operation of the pro-
tective measures provided in the do-
mestic electrical installation and in this
Miele product must also be maintained
in isolated operation or in operation that
is not synchronized with the grid power
supply, or these measures must be re-
placed by equivalent measures in the
installation. As described, for example,
in the current version of VDE-AR-E
2510-2.
If the power cord needs to be replaced,
this must be done by a qualified techni-
cian.