8-7-3. Device
Select Device to set the motion zone, sensor input/alarm output conditions, PTZ control and spot setting conditions.
8-7-3-1. Device
Setting the Motion Zone/Sensitivity: Select the zone where the motion sensor is active. It is necessary to set a
detection frame when PARTIAL ZONE is selected. Select the level of detection sensitivity of the motion sensor.
Sensitivity selections: 1~9 (High sensitivity level)
Partial Zone: If selecting Partial Zone, a button is displayed to the right. Click the button and click (or drag) a grid cell
in the desired detection frame.
Key Tone: Sets On or Off of Key Tone.
Remote Controller ID: Sets an ID number on the supplied remote control for its identification.
Setting a Sensor Input Terminal: Specify a sensor input terminal number and set the type.
SUBMIT: Saves the changes of the setting values.
8-7-3-2. Alarm Out
Setting an Alarm Output Terminal: Sets the alarm output conditions.
Alarm out No.: Specifies the alarm output terminal number (1~4)
Sensor In: Outputs an alarm signal when the specified external sensor input terminal receives an input.
Motion On: Outputs an alarm signal when the specified video input terminal receives a motion detection signal.
Video Loss On: Outputs an alarm signal when a video loss occurs in the specified video input terminal.
Alarm Duration: Sets the duration of the alarm output signal.
Error Alarm: Sets whether to output or not an alarm signal when the error condition occurs.