Specifications
88
A special security access code is required to set the Baud Rate. The code is a four button
sequence which must be entered in the correct order (ENTER, BACK, CANCEL, BACK).
When the access code is entered, the display will indicate the current Baud Rate. To change the
Baud Rate, use the AHEAD button. When the desired rate is indicated, press the ENTER button.
EQUIPMENT WARNING
Remote equipment controlled by this clock should have a warning sign to indicate that the
equipment is remotely controlled. Primary power should be removed from that equipment prior
to any maintenance or repair operations.
SECONDARY CLOCK CONTROL
The MTC-6000 Master Time Clock controls and synchronizes a wide range of secondary clocks.
It will control one variety of Minute Impulse Clocks and one variety of Synchronous Clocks
simultaneously. The Time display is used to select the clock types. The Minutes side of the
display is used to select the Synchronous-wired clock type and the Hours side of the display is
used to select the Impulse clock type.
1. Synchronous Wired Secondary Clocks
The MTC-6000 Master Clock will synchronize a variety of industry standard Synchronous Wired
secondary clocks. The unit may be programmed by the user for the following clocks:
Note: The clock selection code is set to 0: 0, at the factory.
Synchronous Clock Codes
CODE CORRECTION
: 0
CLOCK TYPE
Midwest Time Hourly-8 Seconds @ XX:57:54,
Twelve Hour-14 seconds 5:57:54
: 1 Standard Hourly-35 seconds @ XX:59:25,
Twelve Hour-12 minutes @ 5:12:00
: 2 Standard Hourly-35 seconds @ XX:59:25,
W/Aux Twelve Hour-12 minutes @ 5:12:00, Run Motor power is
removed from XX:59:00 to XX:00:00
: 3 National Hourly Hourly-35 seconds @ XX:00:00
: 4 National 12 Hourly-25 seconds @ XX:00:00,
Twelve Hour-25 minutes @ 6:00:00
Simplex wired synchronous, Cincinnati D10 and Cincinnati D12 wall clocks use Code :00.
Code :01 Does not correct the second hand for these clocks.
Code :02 Requires the use of the highest numbered output circuit. Place the Circuit Control
switch for this circuit to the AUTO position.
Code :03 The second hand on these clocks is not correctable.
Code :04 The second hand on these clocks is not correctable.
Refer to figure 2 & 3 for Code :00, :01, :03 & :04 connecting diagram. Refer to figure 4 for Code
:02 connecting diagram.