User guide
midon design
1WSwitch User Guide Version 1.02 Page 8 of 28
Enable INP = off
Debug = off
Set Clock (d,h,m,s): 01,14,30,00
The options are further defined later in this manual. All are independently
adjustable without using the SET command.
To verify that your setup is working properly, you could next use the TMP
command to perform an immediate sensor reading. The output of the TMP
command should look like the sample below (the exact output will depend on
what type of sensors and how many you have installed).
SUN 14:30:44
Reading Sensors...
Switch #01[C90000005F31C412]=On
Switch #02[4A0000005F3A1512]=On
Switch #05[170000002A345005]=On
Switch #06[4F0000002A15C405]=On
Switch #07[A60000002A30A405]=On
Switch #08[620000002A1B9C05]=Off
Switch #09[410000002A1A3A05]=On
Switch #10[CC0000001FBD2605]=Off
Switch #11[8F0000001FB60105]=Off
Switch #12[E60000001FB82D05]=Off
Switch #13[A20000001FB6C705]=Off
Switch #14[290000005F365412]=Off
J2 Pin 3 Voltage = 00.40V
>
It is highly recommended that you next turn off (or on) all the connected switches.
This will reset the saved state in the EEPROM, which may not match the physical
configuration – the state of all switch sensors is normally preserved through a
power cycle. Use the ONA or OFA command for all DS2406’s (or DS2407) and
the TOG command for DS2405’s.
If there are no apparent errors, you are ready to use 1WSwitch. Enjoy!