User guide

midon design
1WSwitch User Guide Version 1.02 Page 13 of 28
OnBoard ADC Display
Set this to On if you want 1WSwitch to display the output from the on-
board Analog to Digital Converter connected to pin 3 of J2 and referenced to
ground on pin 4 of J2. Use the DAD command to adjust only this parameter.
Debug
Set this to On only if requested to by Midon Design in case trouble-
shooting details are required. Otherwise, your display will be corrupted with
outputs that are meaningless. Use the DEB command to adjust only this
parameter.
Set Clock
Enter the current time here as Day of week (01 = Sunday) followed by Hour,
Minutes, and lastly, Seconds. Use the SCK command to adjust the clock at any
time. Time is entered and displayed in 24 hour (military) format.
6.2. The DIS Display Output
Sample DIS Output
>dis
01 C90000005F31C412 DS2406 OK P
02 4A0000005F3A1512 DS2406 OK P
03 A400000001042829 DS2408 OK P
04 7400000001044629 DS2408 OK P
05 170000002A345005 DS2405 OK P
06 4F0000002A15C405 DS2405 OK P
07 A60000002A30A405 DS2405 OK P
08 620000002A1B9C05 DS2405 OK P
09 410000002A1A3A05 DS2405 OK P
10 CC0000001FBD2605 DS2405 OK P
11 8F0000001FB60105 DS2405 OK P
12 E60000001FB82D05 DS2405 OK P
13 A20000001FB6C705 DS2405 OK P
14 290000005F365412 DS2406 OK P
15 A0000800E93A8F10 DS1820 OK P
16 3D0000004CC69826 DS2438 OK P
Poll interval = 01 minutes
Serial # Display = On
Time Display = Off
OnBoard ADC Display = On
Enable INP = Off
Debug = Off
FRI 20:11:12
6.2.1. DIS output explanations
The DIS commands shows all sensors registered by 1WSwitch. The output
shows the memory locator for the sensor, known as the sensor ID, the sensor