5.5.7. Serial Number Display (SID)
Set this to On if you want TEMP08 to display the 1-wire ID of all sensors during
the DIS display or poll display.
5.6. Set North Command (NOR)
This command is used to calibrate physical North against the electronic North of
the DS2450-based sensor. To use this command, align your physical weather
vane to point North then enter the NOR command. You will be asked to confirm,
do so, and the new North position will then be stored in permenant memory.
5.7. Delete Command (DEL)
The DEL command is used to removed unwanted sensors from the permenant
memory of TEMP08. The sensor number from the DIS display is used to identify
which sensor is to be deleted. Deleting a sensor does not change the sensor
number of any other sensors in the DIS display, however, it may change the
sensor number shown during the polling process. For example, if you have 3
DS2438 voltage sensors and delete the second one, the third one will now show
as Voltage #02 instead of Voltage #03 during a polling display.
5.8. Erase EEPROM command (ERA)
Hopefully, you will never need to use this command, however, if you wish to
completely delete ALL sensors stored in permanent memory, then this command
will do that.
After issuing the ERA command you will be prompted to confirm the operation.
Entering anything other that “Y” will abort the process.
No other data will be erased during this process. All sensor configuration (TYPe
settings), North pointer, and all options will remain the same.
5.9. Reset Counter Command (RST)
The RST command is used to reset the counters of any connected DS2423
counter sensor. Both the A and B counters of the DS2423 will be reset during
this process.