This option will determine if DS2438’s are queried for their temperature display.
DS2438’s are used for many other sensor types and there are times when
displaying their temperature may not be desired. If this is the case, the display of
these temperatures can be suppressed by setting this option off. Use the ETD
command to adjust only this parameter.
Regular Time Display
This option, when set to on, will provide a once-per-minute time display output
from TEMP08. Set the option to Off to suppress this time display. Use the ETI
command to adjust only this parameter.
Display Wind
This option is used to enable or disable Wind Direction conversion from the first
connected DS2450 sensor. DS2450’s are used in older versions of weather
stations for wind direction sensing. Set the option to On to enable this display of
wind direction. Use the EWN command to adjust only this parameter.
Set Clock
Enter the current time here as Day of week (01 = Sunday) followed by Hour,
Minutes, and lastly, Seconds. Use the SCK command to adjust the clock at any
time. Time is entered and displayed in 24 hour (military) format.
5.2. The DISplay Output
Sample DIS Output
TEMP08 v4.04 2014-11-26
MidonDesign.com
01 3000000002202920 DS2450 OK P
02 91000800135B9B10 DS1820 OK P
03 440000001EC34228 DS18B2 OK P
04 590000000007B014 DS2430 OK P
05 21000000032E4E22 DS1822 OK P
06 060000003770D026 DS2438 OK P B
07 D1000000F5868801 DS2401 OK P
08 A400000001042829 DS2408 OK P ?
09 000000000107A829 DS2408 OK P ?
10 9700000000328329 DS2408 OK P ?
11 C200000016A78605 DS2405 OK P
12 3D0000000C8C351D DS2423 OK P C
13 DB0000007520A126 DS2438 OK P V
14 F5000000B6435726 DS2438 OK P V
Sensors = 14
Poll interval = 01 minutes
Temp disp = F