User guide
midon design
TEMP08 User Guide Version 4.0x Page 11 of 25
Command
Description
Syntax
NOR
Set North for a DS2450-based Weather
Station
NOR
RLY
Actuate a specific 1WIO relay, or bits 0 to 3
of any connected DS2408 configured as
TYPe “O”
RLY <relay number> <on|off>
Where <relay number> = 01 to
80 or A for All (the leading zero
is required for relay numbers
less than 10)
RST
Reset both DS2423 counters
RST<sensorid>
SCK
Set Clock
SCK dd, hh, mm, ss<cr>
dd = 01 to 07 (Sunday = 01)
hh = 00 to 23
mm = 00 to 59
ss = 00 to 59
Note 2
SET
Configure all system parameters
SET
SID
Show the Serial Number ID for the 1-Wire
Devices
SID <on|off>
SPT
Set the polling interval
SPT xx
Where xx is a decimal number
from 00 to 99. 00 will disable
polling.
STD
Set Temperature Display type
STD <F|C>
TIM
Display Time from Real Time Clock
TIM
TMP
Display sensor readings of all connected 1-
Wire Devices in either verbose (includes
serial numbers) or non-verbose manner
TMP
TYP
Select the type of DS2408, DS2438 or
DS2423 device. See table 2 for valid
parameters.
TYP<sensorid>
VER
Displays the current version of the software
loaded
VER
WDR
Wind Direction Reverse (in case your Wind
Direction PCB is installed upside down, or in
case you want to show the FROM direction
instead of the TO direction).
WDR <on|off>