HV Disconnecting Combiner Manual

MNPVHV Disco Instructions (continued)
17 | P a g e 1 0 - 065- 1 R E V : J
Shunt Trip
Pole
Channel A Out
Channel B out
Fuse Holder
Fuse Holder
Fuse Holder
Fuse Holder
2 isolated 600v strings for a 2 channel inverter
Fuse Holder
Fuse Holder
Fuse Holder
Fuse Holder
Shunt Trip
Pole
Channel A Out
Channel B out
Fuse Holder
Fuse Holder
Fuse Holder
Fuse Holder
4 isolated 600v strings for a 2 channel inverter
Fuse Holder
Fuse Holder
Fuse Holder
Fuse Holder
Fuse Holder
Fuse Holder
Fuse Holder
Fuse Holder
Fuse Holder
Fuse Holder
Fuse Holder
Fuse Holder
MNPVHV8-DLTL and MNPVHV16-DLTL Combiners
The MNPVHV8-DLTL and MNPVHV16-DLTL Combiners are available in NEMA 3R and NEMA 4X models.
They are split into two sections each with separate positive and negative for each section.
These combiners are fully compatible with the MidNite Solar Rapid Shutdown System.
The MNPV8HV-DLTL allows you to take 4 strings in and combine them into 2 strings out. So String 1 and 2 go
to channel A out and String 3 and 4 go to channel B. Allowing for two MPPT channels out to a transformerless
inverter.
The MNPV16HV-DLTL allows you to take 8 strings in and combine them into 2 strings out. So String 1,2,3 and
4 go to channel A out and String 5,6,7 and 8 go to channel B. Allowing for two MPPT channels out to a
transformerless inverter.