Nottagutter Information Sheet
MidniteNottagutterpreliminaryinformationsheet
TheNottagutterisagenericbreakerboxcapableofsupportingnumerousdifferentapplications.The
primaryfeatureassociatedwiththeNottagutterare:
PositiveDCbattery/inverterbusbarwithfive5/16”diameterstudslocatableoneithersideofenclosure
NegativeDCinverterbusbarwithfour5/16”diameterstudsmountedononehalfof
500ampshunt
NegativeDCbatteryconnectiononsideof500ampshunt.Shuntmaybelocatedoneitherside
15positionterminalbusbarsforleg1&2ACIN,leg1&2ACOUT,NeutralandGround.
MountingembossesforACleg3inandoutorother
insulatedcircuits(MNSBB)
60amp277VAC2polebypassbreakerstandard
60ampinverterACoutputbreakers(specify2,4,6or8)
Centerdinrailmountsuptotwelvesinglepoleorsix2polebreakersinanycombination
Bypasssliderconfigurableforuptofoursinglepoleortwo2pole
breakersononesideand8singlepole
breakersontheotherside.TheeightbreakersmaybeACoutputandACinputtogether.Theeight
breakersmayalsobefour2polebreakers.
FourUltraliteE‐PanelscanmounttoeachNottagutterforOutBack,MagnumandApolloinverters.
Up
totwoSunnyIslandinvertersaccommodatedeasily
175or250ampinverterbreakersmaybeinstalledineachendoftheenclosure
RightandLefthandchargecontrolbrackets maybeinstalledineachendoftheenclosure