KID Manual Firmware Rev 1761

33 | Page
1 0-268-1 REV B
The Kid Solar Charge Controller Instructions
Off at twice per second.
-FUNC: LVD Alarm OFF/AUTO -
This mode will turn on if the battery voltage goes below the AlrmON
set point and turn OFF if it goes above the AlrmOFF Set point.
From the Status Menu: Press Menu Back
Scroll to the Right and select Load and Press Enter
Select FUNC: LVD Alarm
Press the Right button to *ON
Press the Save Button
Press SETUP button to adjust the VoltsOn and VoltsOff set points.
Note:
the AlrmOn/AlrmOFF setpoints are independent from those on the AUX Port.
-FUNC: NightVarOff OFF/AUTO -
Turns the load on for a user selected amount of time after dusk and
before dawn.
From the Status Menu: Press Menu Back
Scroll to the Right and select Load and Press Enter
Select FUNC: NightVarOff
Press the Right button to *Auto
Press the Save Button
Press SETUP button to adjust the how long after dusk and before dawn the load will be turned on.
-FUNC: Hourly OFF/AUTO -
In this mode the clock re-adjusts the time every night by using the PV
panels to detect dusk and dawn, the time it is only an estimate and it does not take into account DST.
From the Status Menu: Press Menu Back
Scroll to the Right and select Load and Press Enter
Select FUNC: Hourly
Press the Right button to *Auto
Press the Save Button
Press SETUP button to set the time the load will turn on and off.
LBD - Low Battery Disconnect
:
The kid includes an adjustable Low battery Disconnect function which allows the user to set an absolute
discharge limit when using a daily function such as Night Light and the life of the batteries doesn't want
to be compromised, it also includes a reconnect voltage set point or it could be reconnected when Float
has been reached, ensuring that the batteries have been fully charged after a LBD (Low Battery
Disconnect).
If a LBD state has occurred the blue LED will blink slowly.
To set up these parameters:
-Press Menu Back button
-Scroll to the right and select <Load> and press Enter
-Press the Setup button
-If OFF appears under the names Lowbatt and Reconn it means the feature is currently disabled.
-Press the Right button to enable the function, now two numbers will appear under the names
-Press the Left, Right, Up and Down keys to adjust the voltages as needed for your battery type
-To enable reconnect on Float stage go to Reconn and Press the Right key again and the word FLOAT