The Kid Solar Charge Controller Instructions
Aux input/output wiring:
This 2 position terminal block is the aux input/output. Functions such as Auto Gen Start, Low Battery
Disconnect or the WhizBang Jr are connected here.
As new features are added they will be available at no cost at
http://www.midnitesolar.com/firmwareIndex.php
Stacking port
Battery temperature
sensor plugged in
Do not allow excess
exposed wire
Sample wiring
showing PV, Load, Battery, Whizbang Jr., BTS and stacking cable.
Wires may exit through either conduit fitting.
One Heyco part # M3200
strain relief is supplied for
the power connections.
Important!
The input and output negative
connections must remain isolated.
Failure to do so will cause inaccurate
current readings and possible damage
to the unit.
One Heyco part # UB-875
bushing is supplied for
other connections.