KID Manual Firmware 1797 REV D

The Kid Solar Charge Controller Instructions
32 | Page
1 0-268-1 REV D
power is available and it will maintain 3 stage battery charging. There are 2 parameters that can be
adjusted when Pressing the SETUP button; Offset and Width
Offset: This is in voltage, and refers to an Offset from the current battery voltage Set point, for example if
the battery charging stage is Absorb then the Offset is taken from the Absorb set point, in the same
manner it will be taken from the other Stages also it takes into account if the Battery temperature sensor
is plugged in and set up.
Width: This is in voltage and refers to the volts the transition will take, from On to Off and vise-versa.
To use PWM Divert Mode do the Following:
From the Status Menu: Press Menu Back
Scroll to the Right and select Load and Press Enter
Select FUNC: PWM Divert
Press the Right button to *ON
Press the Save Button
Press SETUP button to adjust the Offset and Width set points.
- FUNC: Float ON:
The Load will be turned on when the battery state of charge is Float and it will
turn off when the state of charge is any other than Float
To use Float On Mode do the Following:
From the Status Menu: Press Menu Back
Scroll to the Right and select Load and Press Enter
Select FUNC: Float On
Press the Right button to *Auto
Press the Save Button
- FUNC: Float OFF:
The Load will be turned off when the battery state of charge is Float and it will
turn on when the state of charge is any other than Float
To use Float Off Mode do the Following:
From the Status Menu: Press Menu Back
Scroll to the Right and select Load and Press Enter
Select FUNC: Float Off
Press the Right button to *Auto
Press the Save Button
-FUNC: Diversion OFF/AUTO
This function will divert excess power to the load when extra power is
available. This mode is not PWM based. There are 2 parameters that can be adjusted when Pressing
the SETUP button; VoltOn and VoltOff
VoltsOn: This is the absolute voltage, at which the load will be turned on
VoltsOff: This is the absolute voltage, at which the load will be turned off
To use Diversion Mode do the Following:
From the Status Menu: Press Menu Back
Scroll to the Right and select Load and Press Enter
Select FUNC: Diversion
Press the Right button to *ON
Press the Save Button
Press SETUP button to adjust the VoltsOn and VoltsOff set points.
-FUNC: Toggle Test OFF/AUTO
This Mode is for testing purposes only, it will turn the load On and