Kid Manual

The KID Solar Charge Controller Instructions
Auto Gen Start
Important!
Do Not Exceed 1 2VDC at 1 00 mA Relay Drive
Use Normally Open (N.O.) Contacts
Auto Gen Start (AGS) This function will try to start the Generator and while
monitoring battery voltage to assure the generator is charging.
If not, it will signal the generator to shut down to conserve fuel.
Generator On at: Battery voltage level that will trigger the signal to start the generator.
GenStart Delay: Delay in minutes that the battery voltage must be below the
“Generator On at” setting ,To signal the generator to start.
MIN Gen Run Time: Minimum time in minutes the generator will run after Auto Gen Start.
MAX Gen Run Time: Maximum time in minutes the generator will run after Auto Gen Start.
Gen Run Confirm: When the battery voltage has dropped below the set point and the delay
time has been satisfied The KID will begin the process of starting the
generator. The first step it takes is to temporarily disable the solar
charging so it can monitor the battery voltage to verify the generator
actually started. This is called THE "qualifying time". The KID will then
watch the battery voltage to verify that it has risen and confirm that the
generator has started. This is called the "Gen Run Confirm Voltage".
43 | Page 1 0-268-1 REV T