Instruction Manual
The KID Solar Charge Controller Instructions
1 9 | Page
1 0-268-1 REV P7
BATTERY
LOAD
PV
+
-
+
-
+
-
Mounting and Wiring with the wall mount bracket:
IMPORTANT!
Input, output, and load negatives must be isolated. They are not internally connected.
Inaccurate current readings and damage may result from improper wiring.
Load Positive is internally connected to Battery Positive. Loads are switched in the negative leg.
Most KIDs come pre-installed in the wall mount bracket. See page 1 2 if you need to install your KID into the wall
mount bracket. Select an indoor mounting location that is dry and protected from the elements. Try to keep the
wires to the panels, battery bank, and loads as short as possible. Dimensioned drawings are provided in this
manual to aid in installation. The KID with mounting bracket may also be used as a drilling template.
High quality wall anchors are recommended for securing The KID to the wall.
Use caution to avoid any pipes or wires that may be running through the walls.
Unit must be installed in a vertical position and spaced 2 inches from the back wall to allow air to circulate behind
the unit
The terminal block in the housing is factory pre-wired to the internal terminal block inside The KID.
Torque field connections to 1 0 in-lbs (1 .1 3 Nm).
AUX/ WBJr Terminal Block.
To insert a wire:
Strip 5/6" (8mm) and press into the terminal
block until it is seated. Gently tug to ensure
the wire is fully installed.
To remove the wire:
Gently press down on the white plastic next to
the wire while gently pulling the wire out.