User Manual
37 of 39
10-539-1 MN5048DIY REV -
MN5048DIY
User Manual
Peak power
10000VA
Output short-
circuit protection
Specification of
bypass breaker
63A
Rated battery
input voltage
48V (minimum start voltage 44V)
Battery voltage
range
40.0Vdc~60Vdc ±0.6Vdc (undervoltage alarm/turnoff
voltage/overvoltage alarm/overvoltage restoration…settable LCDscreen)
Power saving
mode
Load ≤ 50W
Frequency range
Lead acid or lithium battery
Battery type
Maximum charge
current
Charge current
error
±5Adc
Overcharge
protection
Turn off charge after 1min alarm
Maximum PV open
-circuit voltage
500Vdc
PV operation
voltage range
120-500Vdc
Battery voltage
range
Maximum
output power
Loaded motor
capacity
4HP
Breaker
AC charge
40A
Charge voltage
range
40–60Vdc
Breaker
specification
63A
Solar charge
MPPT voltage
range
120-450Vdc
40-60Vdc
5000W
Charge current
range of solar
energy(settable)
0-80A
Charge short-
circuit protection
Blown fuse
Wiring protection Inverse wiring protection