4.3 Battery type parameters
For Lead -acid Battery :
Battery type
Parameters
Sealed lead
acid battery
(SLD)
Colloidal lead
acid battery
(GEL)
Vented lead
acid battery
(FLD)
User - defined
(User)
Overvoltage disconnection
voltage
60V 60V 60V 36~60V
Equalizing charge voltage
58.4V 56.8V 59.2V 36~60V
Absorption charge voltage
57.6V 56.8V 58.4V
36~60V
(Adjustable)
Float charge voltage
55.2V 55.2V 55.2V
36~60V
(Adjustable)
Undervoltage alarm voltage
44V 44V 44V
36~60V
(Adjustable)
Low voltage disconnection
voltage
42V 42V 42V
36~60V
(Adjustable)
Discharge limit voltage
40V 40V 40V
36~60V
(Adjustable)
Over-discharge delay time
5s 5s 5s
1~30s
(Adjustable)
Equalizing charge duration
120 minutes
-
120
minutes
0~600
minutes
(Adjustable)
Equalizing charge interval
30 days
-
30 days
0~250
days
(Adjustable)
Absorption charge duration
120 minutes 120 minutes
120
minutes
10~600
minutes