DIY User Manual
24 of 39
10-539-1 MN5048DIY REV -
MN5048DIY
User Manual
Parameter
no.
Parameter
name
Settings Description
06
Charger
source
priority
[06] CSO
PV priority charging ; when not PV is unavailable,
charging from the mains is started.
[06] CUB
M ains priority charging; When charging from the
mains is not available PV charging is started.
[06] SNU default
PV and Mains hybrid charging; PV charging is a
priority, and when the PV energy is insufficient,
the Mains charging supplements. When the PV
energy is sufficient, the Mains charging stops.
Note: Only when the Mains bypass output is
loaded, the PV charging and the mains
charging can work at the same time. When the
inverter is in use, only the PV charging can be
started.
[06] OSO
Only PV charging, with the Mains charging not
activated.
07
Max charger
current
[07] 60A default
Max charger current (AC charger+PV charger).
Setting range: 0~80A
08 Battery Type
[08] USE User-defined ; all battery parameters can be set.
[08] SLd
Sealed lead - acid battery;
absorption charge Voltage: 57.6V,
float charge voltage: 55.2V
[08] FLd
Vented lead-acid battery;
absorption charge voltage: 58.4V,
float charge voltage: 55.2V
[08] GEL default
Colloidal lead- acid battery;
absorption charge voltage: 56.8V
float charge voltage: 55.2V
;
[08]
LL14/L15/L16
Lithium iron phosphate battery L14/L15/L16
corresponds to lithium iron phosphate battery
14 strings/15 strings/16 strings;16 string/15
string/14 string default constant
The charging voltage is 56.8V, 53.2V,
49.6V, which are adjustable.