DIY User Manual
14 of 39
10-539-1 MN5048DIY REV -
MN5048DIY
User Manual
PV input wiring method:
PV+: PV input positive pole PV -: PV input negative pole
① Prior to wiring, disconnect the external circuit breaker and confirm
that the wire used is appropriate AWG. Please refer to Section 2.2
“Wiring Specifications and Circuit Breaker Selection”;
② Properly connect the PV input wire according to the wire
sequence and terminal posion shown in the figure below.
BATTERY wiring:
① Prior to wiring, disconnect the external circuit breaker and confirm
that the wire used is appropriate AWG. Please refer to Section 2.2
“Wiring Specifications and Circuit Breaker Selection”. The BAT wire
needs to be connected to the MNS Hybrid Inverter using a copper ring
terminal either setscrew or crimp type is acceptable. Insure the crimp is
tight if using crimp style to prevent excessive heat generation caused by
excessive contact resistance from a loose terminal;
② Properly connect the BAT wire according to the wire sequence
and terminal position shown in the figure on the next page.