This mode will cycle Aux 2 for 1 second off and 1 second on repeatedly. This mode is mostly for testing
purposes.
Waste Not Lo
This mode is PWM based and is just reverse logic of Waste Not Hi. It would be comparable to using the
NC contacts of the relay used in Waste Not Hi. It can be used that way with a solid state relay and NC
contacts to do diversion above a set voltage.
Waste Not Hi
This mode is PWM based and will PWM Aux 2 when the Classic gets within a certain range of the
voltage set points for each charging stage (V High) and stop when it gets to a low set point (V Low).
These set points are user adjustable and will allow the Absorb, Float and EQ timers to continue to run.
You will adjust these set points to negative numbers and the numbers are an offset from the voltage set
point. For example a -0.2 would turn Aux 2 on 2 tenths of a volt below your set points. This mode will
allow you maximum diversion while maintaining your 3 stage charging.
Diversion Lo
This mode is PWM based and is just reverse logic of Diversion Hi. It would be comparable to using the
NC contacts of the relay used in Diversion Hi. It can be used that way with a solid state relay and NC
contacts to do diversion above a set voltage.
Diversion Hi
This mode is PWM based and will PWM Aux 2 at a set point based on battery voltage (V High) and stop
it at another set point based on battery voltage (V Low).
Aux 1 Function
OUTPUT = Relay or 12V/0V Signal jumper selectable, ON/OFF Function. (Dry Contact 1A max)
Aux 1 has the relay so Diversion functions must operate slowly