Installation Guide

Classic owner’s manual Rev I 2193
32 |
P a g e 1 0 - 0 0 1 - 1 R E V : I
will not charge the battery. If you see ―Mode is Off‖ in the bottom right corner of the display then the
Mode may have been turned off. To turn the mode back ―ON‖ push the Main Menu button several times
until ―Charge‖ is highlighted. Scroll to the right until ―Mode‖ is highlighted and press ―Enter‖. On this
screen ―OFF‖ should be highlighted use the up or down arrow to change it to ―ON‖ and press ―Enter‖.
Press the Status button once to return to the main status screen.
Note: This is the same menu you would use to change between Charging algorithms IE Solar, Hydro,
Windetc.
Adjusting Absorb, Equalize and Float Voltages
Absorb, Equalize and Float voltages are fully adjustable. You will need to get the actual voltages from the
battery manufacturer. To adjust these voltages follow the steps below.
Press Main Menu to enter the Main Menu
Scroll right or left until Charge is highlighted and push the Enter button
Highlight Volts and press the Enter button
Use left and right arrow keys to highlight the set point voltage to adjust
Use up and down arrow keys to lower or raise the voltage
Press the Enter button to save the new voltages.
Current Limit
The Classic has a current limit component which interacts with the temperature of the charge controller.
If the Classic is exposed to extremely hot ambient conditions the output current will be reduced
automatically to keep the charge controller safe. If the orange LED comes on the MNGP, it means that the
Classic is in current limit mode. If you believe the Classic is not hot and the orange LED is on, most likely
the current limit set point is too low. To check this, follow steps below.
Press Main Menu
Highlight the CHARGE menu and press the Enter Button
Scroll to LIMITS and press the Enter Button
Press the right arrow key to highlight ―Out Amps‖ or ―In Amps‖ column
Use the up and down arrow keys to change the current limit then press the Enter Button to save
this data
LED Modes and the ―Blinking Red LED‖
Below we will explain the different LED Modes. To change the LED Mode press the ―Main Menu‖ button
repeatedly until ―Charge‖ is highlighted. Scroll to the right until ―Misc‖ is highlighted and press ―Enter‖.
Now scroll to ―LED-Mode‖ and press ―Enter‖. Here you can use the up and down arrows to select the
mode you prefer. After selecting the appropriate LED Mode press ―Enter‖ to save this data to the Classic.
Pressing ―Status‖ will now bring you back to the home screen.
OFF = No LED activity no matter what
Rick Mode = LED Activity for Errors and Warnings only. (Over current, Arc Fault Etc.)