Installation Guide

Classic owner’s manual Rev I 2193
27 |
P a g e 1 0 - 0 0 1 - 1 R E V : I
DC Terminal Connector
Figure 17
The Classic's DC terminal connector is located on the circuit board as shown in figure 17. The connector
will take up to a #4 AWG. #4 AWG THHN when installed in the Classic and MidNite E-Panel is rated for
over 100 amps and is therefore suitable for the highest power available from the Classic 150. After
installing the wires for the last time snap in the blue cover that is included in the parts bag.
Over Current Protection and Wire Size Requirements
The over current devices, wiring, and installation methods used must conform to all electrical codes
applicable to the location of installation. Wiring needs to be protected with proper strain relief clamps and
or conduit. See page 76for a breaker and wire size chart.
The network cables, USB cable, BTS cable and auxiliary input/output cables should run in a different
conduit to preserve their signal. When installing the Classic in a MidNite E-Panel, it is acceptable to run
all wiring through the same knockout hole. It is legal to run signal and power wires together as long as all
wiring is listed for the highest voltage to be encountered. (Follow all local code)
Current Rating
The Classic limits the output current based on the model you have.
The Classic current ratings are:
Classic 150 - 96amps maximum
Classic 200 - 79 amps maximum
Classic 250 - 62 amps maximum